MTCBA-C1-N16 Multi-Tech Systems, MTCBA-C1-N16 Datasheet - Page 52

no-image

MTCBA-C1-N16

Manufacturer Part Number
MTCBA-C1-N16
Description
MODEM ETHERNET
Manufacturer
Multi-Tech Systems
Datasheets

Specifications of MTCBA-C1-N16

Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Aeris Networks (USA)
Interface
RS-232
Data Rate - Maximum
153.6 kbps
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4976016

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MTCBA-C1-N16
Manufacturer:
Multi-Tech Systems
Quantity:
135
Cell Environment and RxLev Indication +CCED
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
This command can be used by the application to retrieve information about the main cell and up
to six neighboring cells. This is an extended command that may be used in two different
The +CCED command supports two modes of operation: on request by the application or
automatically by the product every 5 seconds. Signal strength can also be reported when the
change exceeds a threshold.
Command syntax: AT+CCED=<mode>[, <requested dump>[,<sqStep>]]
<mode>
<requested dump> This parameter is specified as the summation of one or more of the
<CsqStep>
Command
AT+CCED=?
AT+CCED?
Note: <requested dump> is the most
recently requested one. If none
requested, <requested dump>=1 will be
displayed.
AT+CCED=0
Note: One time dump of the <requested
dump> that was last requested. If none
requested, <requested dump>=1 will be
displayed
AT+CCED=0,1
Note: one time, dump main cell
AT+CCED
Note: one time, previous <requested
dump> value is used
AT+CCED =0,9
AT+CCED=1,8
Note: Start automatic snapshots and
dump <rssi>.
AT+CCED=2
AT+CCED=,,1
AT+CCED=1,9
Note: Start automatic snapshots and
dump cell environment and <rssi>
1. Interrogation of the cell environment information
2. Interrogation of the received signal strength indication (RSSI)
0
1
2
1
2
0
1-5:
Requests a single snapshot of cell data
Start automatic snapshot mode. The unsolicited responses +CCED and/or
+CSQ will be used to return the requested information.
Stop automatic snapshot mode
following values:
Main Cell Indication
Main Cell RSSI Indication (RxLev) from 0 to 31 and frame error rate. Set
the AT+CSQ command description for more information.
Unsolicited +CSQ reports due to changing RSSI levels are disabled.
Whenever the RSSI changes by this amount or more, an unsolicited +CSQ
report is generated.
Possible Responses
+CCED: (0-2),(1,8,9),(1-5)
OK
+CCED: 0,1,0
OK
+CSQ: 15, 99
or
+CCED: 0,160,69,101,6,144,2690,2,18,-85,-51,-63
OK
+CCED: 0,160,69,101,6,144,2690,2,18,-85,-51,-63
OK
+CCED: 0,160,69,101,6,144,2690,2,18,-85,-51,-63
OK
+CSQ: 15, 99
+CCED: 0,160,69,101,6,144,2690,2,18,-85,-51,-63
OK
OK
+CSQ: 18, 99
Note: +CSQ response output every 5 seconds.
OK
Note: Stop automatic snapshots.
OK
+CSQ: 18, 99
Note: New +CSQ response output when change in
RSSI equals or exceeds <CsqStep>
OK
+CSQ: 15, 99
+CCED: 0,160,69,101,6,144,2690,2,18,-85,-51,-63
Chapter 10 – Network Service Commands
settings:
52