CL4424-100-485 Laird Technologies, CL4424-100-485 Datasheet - Page 14

TXRX 2.4GHZ RS232 100MW W/ANT

CL4424-100-485

Manufacturer Part Number
CL4424-100-485
Description
TXRX 2.4GHZ RS232 100MW W/ANT
Manufacturer
Laird Technologies
Series
AeroCommr
Datasheets

Specifications of CL4424-100-485

Function
Transceiver
Modulation Or Protocol
FHSS, FSK
Frequency
2.4GHz
Applications
General Purpose
Interface
RS-485
Sensitivity
-99dBm
Power - Output
100mW
Data Rate - Maximum
288kbps
Features
RS-485
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Wireless Frequency
2.4 GHz
Interface Type
RS-232, RS-485
Board Size
121 mm x 70 mm x 30 mm
Modulation
FHSS, FSK
Security
1 Byte System ID
Output Power
100 mW
Antenna
Dipole, RPSMA Jack
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CL4424 User’s Manual
2.3
Hardware Flow Control
Often, the host device can send data to the CL4424 faster than it can be sent over the RF. The
CL4424 has a 256 byte buffer to store data before sending it over the RF. If the host device is
sending data faster than the CL4424 can send it out, eventually, the buffer will fill up. If the host
device continues to send data while the CL4424 buffer is full, that data will be discarded. To
avoid this situation, the CL4424 will de-assert CTS as a warning that the buffer is filling. The host
device should stop sending data. When the CL4424 is able to free some buffer space, it will
assert CTS and the host device can continue sending data. Similarly, if RTS is enabled in the
CL4424, the host device can throttle the CL4424 by de-asserting RTS. Note: CTS is always
enabled by default. RS-485 Interface does not support Hardware flow control and RTS mode
should not be enabled on a RS-485 CL4424.
6/21/2005
14