CL4424-100-485 Laird Technologies, CL4424-100-485 Datasheet - Page 19

TXRX 2.4GHZ RS232 100MW W/ANT

CL4424-100-485

Manufacturer Part Number
CL4424-100-485
Description
TXRX 2.4GHZ RS232 100MW W/ANT
Manufacturer
Laird Technologies
Series
AeroCommr
Datasheets

Specifications of CL4424-100-485

Function
Transceiver
Modulation Or Protocol
FHSS, FSK
Frequency
2.4GHz
Applications
General Purpose
Interface
RS-485
Sensitivity
-99dBm
Power - Output
100mW
Data Rate - Maximum
288kbps
Features
RS-485
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Wireless Frequency
2.4 GHz
Interface Type
RS-232, RS-485
Board Size
121 mm x 70 mm x 30 mm
Modulation
FHSS, FSK
Security
1 Byte System ID
Output Power
100 mW
Antenna
Dipole, RPSMA Jack
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CL4424 User’s Manual
4.3
1. Connect a CL4424 unit to the serial communications port on the PC.
2. Connect the power supply to the CL4424 unit. Make sure the Pwr LED is on.
3. Start the CL4424 Configuration Utility.
4. Select the COM Port that is connected to the CL4424 unit on the PC Settings section.
5. Select the Interface Baud Rate of the CL4424 unit. All CL4424 units are shipped with a
6. Select the System Configuration for the CL4424 network, Point-to-Point (one Server and one
7. Select Read Radio to display the current settings of the CL4424 unit.
8. Change desired settings.
9. After all changes have been made, select Write Radio to save the changes.
10. Cycle Power to the unit after all changes has been saved. This will set the CL4424 unit to its
6/21/2005
default rate of 115,200 bps (unless units have been pre-configured to match specific serial
settings). If the Interface Baud Rate of the CL4424 unit is changed as described in Section
4.2 Changing CL4424 Settings, then PC Setting Baud Rate must be set to the same Baud
Rate to allow proper programming of the units.
Client) or Point-to-Multipoint (one Server and multiple Clients).
normal mode of operation.
Programming The CL4424 units
19