XB24-AWI-001 Digi International/Maxstream, XB24-AWI-001 Datasheet - Page 29

no-image

XB24-AWI-001

Manufacturer Part Number
XB24-AWI-001
Description
MODULE 802.15.4 1MW W/WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XBee™r
Datasheets

Specifications of XB24-AWI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
50mA
Current - Transmitting
45mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Table 3‐02. XBee®/XBee‐PRO® Commands ‐ Networking & Security (Sub‐categories designated within {brackets})
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
AT
Command
NO (v1xC5)
DN ( v1.x80*)
CE ( v1.x80*)
SC ( v1.x80*)
SD ( v1.x80*)
A1 ( v1.x80*)
A2 ( v1.x80*)
Command
Category
Networking
{Identification}
Networking
{Identification}
Networking
{Association}
Networking
{Association}
Networking
{Association}
Networking
{Association}
Networking
{Association}
Name and Description
Node Discover Options. Enables node discover self-response on the module.
Destination Node. Resolves an NI (Node Identifier) string to a physical address. The
following events occur upon successful command execution:
If there is no response from a module within 200 msec or a parameter is not specified
(left blank), the command is terminated and an “ERROR” message is returned.
Coordinator Enable. Set/Read the coordinator setting.
Scan Channels. Set/Read list of channels to scan for all Active and Energy Scans as a
bitfield. This affects scans initiated in command mode (AS, ED) and during End Device
Association and Coordinator startup:
Scan Duration. Set/Read the scan duration exponent.
End Device - Duration of Active Scan during Association.
Coordinator - If ‘ReassignPANID’ option is set on Coordinator [refer to A2 parameter],
SD determines the length of time the Coordinator will scan channels to locate existing
PANs. If ‘ReassignChannel’ option is set, SD determines how long the Coordinator will
perform an Energy Scan to determine which channel it will operate on.
‘Scan Time’ is measured as (# of channels to scan] * (2 ^ SD) * 15.36ms). The number
of channels to scan is set by the SC command. The XBee can scan up to 16 channels
(SC = 0xFFFF). The XBee PRO can scan up to 13 channels (SC = 0x3FFE).
Example: The values below show results for a 13 channel scan:
End Device Association. Set/Read End Device association options.
bit 0 - ReassignPanID
bit 1 - ReassignChannel
bit 2 - AutoAssociate
Note: This bit is used only for Non-Beacon systems. End Devices in Beacon-enabled
system must always associate to a Coordinator
bit 3 - PollCoordOnPinWake
bits 4 - 7 are reserved
Coordinator Association. Set/Read Coordinator association options.
bit 0 - ReassignPanID
bit 1 - ReassignChannel -
bit 2 - AllowAssociation -
bits 3 - 7 are reserved
© 2009 Digi Internatonal, Inc.
1. DL and DH are set to the address of the module with the matching Node Identifier.
2. “OK” is returned.
3. RF module automatically exits AT Command Mode
bit 0 - 0x0B
bit 1 - 0x0C
bit 2 - 0x0D
bit 3 - 0x0E
If SD = 0, time = 0.18 sec SD = 8, time = 47.19 sec
SD = 2, time = 0.74 sec
SD = 4, time = 2.95 sec
SD = 6, time = 11.80 sec
0 - Will only associate with Coordinator operating on PAN ID that matches module ID
1 - May associate with Coordinator operating on any PAN ID
0 - Will only associate with Coordinator operating on matching CH Channel setting
1 - May associate with Coordinator operating on any Channel
0 - Device will not attempt Association
1 - Device attempts Association until success
0 - Pin Wake will not poll the Coordinator for indirect (pending) data
1 - Pin Wake will send Poll Request to Coordinator to extract any pending data
0 - Coordinator will not perform Active Scan to locate available PAN ID. It will operate
1 - Coordinator will perform Active Scan to determine an available ID (PAN ID). If a
0 - Coordinator will not perform Energy Scan to determine free channel. It will operate
1 - Coordinator will perform Energy Scan to find a free channel, then operate on that
0 - Coordinator will not allow any devices to associate to it.
1 - Coordinator will allow devices to associate to it.
on ID (PAN ID).
PAN ID conflict is found, the ID parameter will change.
on the channel determined by the CH parameter.
channel.
bit 4 - 0x0F
bit 5 - 0x10
bit 6 - 0x11
bit 7 - 0x12
SD = 10, time = 3.15 min
SD = 12, time = 12.58 min
SD = 14, time = 50.33 min
bit 8 - 0x13
bit 9 - 0x14
bit 10 - 0x15
bit 11 - 0x16
bit12 - 0x17
bit13 - 0x18
bit14 - 0x19
bit 15 - 0x1A
Parameter Range
0-1
0 - 1
0 - 0xFFFF [bitfield]
(bits 0, 14, 15 not allowed on
the XBee-PRO)
0-0x0F [exponent]
0 - 0x0F [bitfield]
0 - 7 [bitfield]
20-character ASCII string
0 = End Device
1 = Coordinator
Default
0
-
0
0x1FFE
(all XBee-
PRO
Channels)
4
0
0
     29

Related parts for XB24-AWI-001