Specifications of XB24-AWI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
50mA
Current - Transmitting
45mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
IO (Digital Output Level) Command
IR (Sample Rate) Command
IS (Force Sample) Command
IT (Samples before TX) Command
<I/O Settings> The IO command is used to set
digital output levels. This allows DIO lines setup
as outputs to be changed through Command
Mode.
<I/O Settings> The IR command is used to set/
read the sample rate. When set, the module will
sample all enabled DIO/ADC lines at a specified
interval. This command allows periodic reads of
the ADC and DIO lines in a non-Sleep Mode
setup. A sample rate which requires transmis-
sions at a rate greater than once every 20ms is
not recommended.
Example: When IR = 0x14, the sample rate is 20 ms (or 50 Hz).
<I/O Settings> The IS command is used to force
a read of all enabled DIO/ADC lines. The data is
returned through the UART.
When operating in Transparent Mode (AP=0), the
data is retuned in the following format:
All bytes are converted to ASCII:
When operating in API mode (AP > 0), the command will immediately return an ‘OK’ response.
The data will follow in the normal API format for DIO data.
<I/O Settings> The IT command is used to set/
read the number of DIO and ADC samples to col-
lect before transmitting data.
One ADC sample is considered complete when all
enabled ADC channels have been read. The mod-
ule can buffer up to 93 Bytes of sample data.
Since the module uses a 10-bit A/D converter, each sample uses two Bytes. This leads to a maxi-
mum buffer size of 46 samples or IT=0x2E.
When Sleep Modes are enabled and IR (Sample Rate) is set, the module will remain awake until IT
samples have been collected.
© 2009 Digi Internatonal, Inc.
number of samples<CR>
channel mask<CR>
DIO data<CR> (If DIO lines are enabled<CR>
ADC channel Data<cr> <-This will repeat for every enabled ADC channel<CR>
<CR> (end of data noted by extra <CR>)
AT Command: ATIO
Parameter Range: 8-bit bitmap
(where each bit represents the level of an I/O
line that is setup as an output.)
Minimum Firmware Version Required: v1.xA0
AT Command: ATIR
Parameter Range: 0 - 0xFFFF [x 1 msec]
(cannot guarantee 1 ms timing when IT=1)
Default Parameter Value:0
Related Command: IT (Samples before TX)
Minimum Firmware Version Required: v1.xA0
AT Command: ATIS
Parameter Range: 1 - 0xFF
Default Parameter Value:1
Minimum Firmware Version Required: v1.xA0
AT Command: ATIT
Parameter Range: 1 - 0xFF
Default Parameter Value:1
Minimum Firmware Version Required: v1.xA0