ETRX2 Telegesis Ltd, ETRX2 Datasheet - Page 24

MODULE ZIGBEE EM250 CHIP ANT

ETRX2

Manufacturer Part Number
ETRX2
Description
MODULE ZIGBEE EM250 CHIP ANT
Manufacturer
Telegesis Ltd
Datasheets

Specifications of ETRX2

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee
Applications
ISM
Power - Output
3dBm
Sensitivity
-98dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
35.5mA
Current - Transmitting
35.5mA
Data Interface
PCB, Surface Mount
Memory Size
128kB Flash, 5kB SRAM
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Module Applications
AMR, Building Automation, Wireless Sensor Network, M2M Industrial Controls
Mcu Supported Families
EM250
Processor Type
EM250
Wireless Protocol
IEEE 802.15.4
Data Rate
250Kbps
Module Interface
I2C, SPI, UART
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
920-1000-2
16 Reliability Tests
The measurements were conducted after the module being exposed to room temperature and
humidity for 1 hour.
No
1
2
3
4
5
6
17 Application Notes
17.1 Safety Precautions
17.2 Design Engineering Notes
©2009 Telegesis (UK) Ltd
These specifications are intended to preserve the quality assurance of products as individual
components.
Before use, check and evaluate their operation when mounted on your products. Abide by
these specifications, without deviation when using the products. These products may short-
circuit. If electrical shocks, smoke, fire, and/or accidents involving human life are anticipated
when a short circuit occurs, then at least, provide the following failsafe functions, as a
minimum:
(1)
(2)
(3)
(4)
(5)
Item
Vibration test
Shock test
Heat cycle test
Moisture test
Low temp. test
High temp. test
Ensure the safety of the whole system by installing a protection circuit and a protection
device.
Ensure the safety of the whole system by installing a redundant circuit or another
system to prevent a single fault causing an unsafe status.
Heat is the major cause of shortening the life of these products. Avoid assembly and
use of the target equipment in conditions where the product’s temperature may exceed
the maximum allowable.
Failure to do so may result in degrading of the product’s functions and damage to the
product.
If pulses or other transient loads (a large load applied in a short time) are applied to the
products, before use, check and evaluate their operation when assembled onto your
products.
Limit
Electrical parameter should be
in specification
the same as the above
the same as the above
the same as the above
the same as the above
the same as the above
Table 12: Reliability Tests
- 24 -
ETRX2 Product Manual (Rev 1.09)
Condition
a) Freq.:10~50Hz,Amplitude:1.5mm
a) 20min. / cycle,1hrs. each of XYZ axis
b) Freq.:30~100Hz, 6G
b) 20min. / cycle,1hrs. each of XYZ axis
Dropped onto hard wood from height of
50cm for 3 times
-40°C for 30min. and +85°C for 30min.;
each temperature 300 cycles
+60°C, 90% RH, 300h
-40°C, 300h
+85°C, 300h