E3S-CT11 Omron, E3S-CT11 Datasheet - Page 13

SENSOR PHOTO HORZ 98' THRUBEAM

E3S-CT11

Manufacturer Part Number
E3S-CT11
Description
SENSOR PHOTO HORZ 98' THRUBEAM
Manufacturer
Omron
Series
E3S-Cr
Type
Long Range Metal Body Sensorr
Datasheets

Specifications of E3S-CT11

Sensing Distance
1181.102" (30m)
Sensing Method
Through-Beam
Output Configuration
PNP - Dark-ON/Light-ON - Selectable
Mounting Type
Bracket Mount, Horizontal
Current - Supply
50mA
Voltage - Supply
10 V ~ 30 V
Response Time
1ms
Package / Case
Module, Pre-Wired
Features
Mutual interference protection
Height
29.5 mm
Length
50 mm
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Width
40.4 mm
Light Source
Infrared LED
Connection
Prewired Cable
Output Current
100mA
Supply Voltage Range Dc
10V To 30V
Sensor Housing
Rectangular
Sensor Input
Optical
Sensing Range Max
30m
Switch Terminals
Wire Leaded
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS compliant by exemption
Other names
E3SCT11
Z1102

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3S-CT11
Manufacturer:
OMRON
Quantity:
264
Part Number:
E3S-CT11-D
Manufacturer:
OMRON
Quantity:
475
Part Number:
E3S-CT11-L
Manufacturer:
XG
Quantity:
11 700
Precautions
J CONNECTION
If the input/output lines of the photoelectric sensor are placed in the
same conduit or duct as power lines or high-voltage lines, the photo-
electric sensor could be induced to malfunction, or be damaged, by
the electrical noise. Either separate the wiring, or use shielded lines
as input/output lines to the photoelectric sensor.
The cord connected to the E3S-C can be extended up to 100 m pro-
vided that the diameter of each wire of the cord is 0.3 mm
J POWER SUPPLY
If the standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal, on the
power supply, must be grounded. If this is not done the E3S-C may
malfunction, due to the switching noise of the power supply.
If an inverter motor or servomotor is used with the E3S-C, the frame
ground (FG) terminal and the ground (G) terminal, on the motor,
must be grounded, otherwise the E3S-C may malfunction.
Installation
J MOUNTING
Use M4 screws to mount the E3S-C. The tightening torque of each
screw must be 12 kgf S m (1.18 N S m) maximum.
J DIRECT MOUNTING
Mount the E3S-C as shown in the following illustrations.
E3S-C
M4
M4 hole
M4 hole
Two, M3
Two, 4.5 dia.
through holes
M4 hole
M4 hole
M3
2
minimum.
J WATER RESISTANCE
To ensure the water resistance of the E3S-C, tighten the screws of
the operation panel cover to a torque of 3.5 to 5.5 kgf S cm (0.34 N S
m to 0.54 N S m).
J OPTICAL AXIS OF THROUGH-BEAM
The E3S-C through-beam models incorporate two lenses, one of
which will be used as shown in the following illustration. When using
a slit, the slit must be on the side where the lens is located.
SENSOR
Lens in use. The slit
must be on this side.
Lens not in use.
E3S-C
13