MPXA4100A6U Freescale Semiconductor, MPXA4100A6U Datasheet - Page 5

PRESSURE SENS 16.7PSI MAX 8-SOP

MPXA4100A6U

Manufacturer Part Number
MPXA4100A6U
Description
PRESSURE SENS 16.7PSI MAX 8-SOP
Manufacturer
Freescale Semiconductor
Series
MPXA4100r
Datasheet

Specifications of MPXA4100A6U

Pressure Type
Absolute
Operating Pressure
2.9 ~ 15.2 PSI
Output
0 ~ 4.9V
Voltage - Supply
4.85 V ~ 5.35 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
8-SOP
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5.1 V
Output Voltage
4.87 V to 5.032 V
Operating Pressure Range
20 To 105kPa
Connection Size
6.35mm
Sensitivity, V/p
54mV/kPa
Supply Current
7mA
No. Of Pins
8
Supply Voltage Range
4.85V To 5.35V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Contains lead / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPXA4100A6U
Manufacturer:
FREESCALE
Quantity:
20 000
Sensors
Freescale Semiconductor
On-chip Temperature Compensation and Calibration
chip carrier (Case 867). A fluorosilicone gel isolates the die
surface and wire bonds from the environment, while allowing
the pressure signal to be transmitted to the sensor
diaphragm. The MPX4100A series pressure sensor
operating characteristics, and internal reliability and
qualification tests are based on use of dry air as the pressure
media. Media, other than dry air, may have adverse effects on
sensor performance and long-term reliability. Contact the
factory for information regarding media compatibility in your
application.
Figure 2
illustrates an absolute sensing chip in the basic
Figure 3. Recommended Power Supply Decoupling and Output Filtering
(For output filtering recommendations, refer to Application Note AN1646.)
Lead Frame
Wire Bond
Fluoro Silicone
Gel Die Coat
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
Figure 2. Cross-Sectional Diagram (not to scale)
0
1.0 μF
Figure 4. Output versus Absolute Pressure
TEMP = 0 to 85°C
20 kPa to 105 kPa
MPX4100A
Transfer Function:
V
VS = 5.1 Vdc
OUT
= V
S
* (.01059*P-0.1518) ± Error
Pressure (ref. to sealed vacuum) in kPa
0.01 μF
Absolute Element
V
s
+5 V
GND
P2
IPS
MAX
interfacing the output of the integrated sensor to the A/D input
of a microprocessor or microcontroller. Proper decoupling of
the power supply is recommended.
pressure input. Typical, minimum, and maximum output
curves are shown for operation over a temperature range of
0° to 85°C using the decoupling circuit shown in
(The output will saturate outside of the specified pressure
range.)
V
out
Figure 3
Figure 4
MIN
Stainless Steel
Metal Cover
shows the recommended decoupling circuit for
shows the sensor output signal relative to
470 pF
Output
TYP
Die
Bond
Epoxy Plastic
Case
Pressure
Figure
MPX4100A
3.
5

Related parts for MPXA4100A6U