SENSOR 20" H2O D MV DUAL

20 INCH-D-MV

Manufacturer Part Number
20 INCH-D-MV
Description
SENSOR 20" H2O D MV DUAL
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 20 INCH-D-MV

Pressure Type
Differential
Operating Pressure
0.07 PSI, 20" H20
Port Size
Male, 0.174" ~ 0.19" (4.4mm ~ 4.8mm) Tube, Dual
Output
0 ~ 20mV
Voltage - Supply
16V
Termination Style
PCB
Operating Temperature
-25°C ~ 85°C
Package / Case
6-SIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
442-1040
Pressure Sensor Ratings
Performance Characteristics for 1 INCH-D-MV
Supply Voltage VS, max
Common-mode pressure
Lead Temperature, max
(soldering 2-4 sec.)
Performance Characteristics for 2 INCH-D-MV
Standard Pressure Ranges
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 1“H2O, note 5
Output Span, @ 4“H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-50°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Full Scale Shift (0°C-50°C), note 2
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-50°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Full Scale Shift (0°C-50°C), note 2
Part Number
1 INCH-D-MV
2 INCH-D-MV
5 INCH-D-MV
10 INCH-D-MV
20 INCH-D-MV
30 INCH-D-MV
Operating Pressure
0 - 10 “H2O
0 - 20 “H2O
0 - 30 “H2O
0 - 1 “H2O
0 - 2 “H2O
0 - 5 “H2O
-10 to +10 psig
16 Vdc
Nominal Span
250°C
Minimum
Minimum
10 mV
20 mV
20 mV
20 mV
20 mV
10mv
36.0
9.0
9.0
Environmental Specifications
Temperature Ranges
Compensated
Operating
Storage
Humidity Limits
Nominal
Nominal
1 to 4
10.0
40.0
10.0
0.05
0.05
2.0
Proof Pressure
100 “H2O
100 “H2O
200 “H2O
200 “H2O
200 “H2O
200 “H2O
Millivolt Low pressure sensors
Maximum
Maximum
±500
±250
±100
±200
±200
±500
±250
±100
±200
±200
11.0
44.0
0.25
11.0
0.25
±50
±50
(non condensing)
Burst Pressure
0 to 50(70)° C
-40 to 125° C
“H2O
“H2O
0 to 95% RH
Units
Units
-25 to 85° C
200 “H2O
200 “H2O
300 “H2O
300 “H2O
500 “H2O
800 “H2O
%fs
mV
mV
%fs
mV
uV
uV
uV
uV
uV
uV
uV
uV
uV
uV
uV
uV