SENSOR 500PSIA COMP RATIO OUT
Manufacturer
Honeywell Sensing and Control
Series
13 mmr
Datasheet

Specifications of 13C500PA4K

Pressure Type
Absolute
Operating Pressure
500 PSI
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
148 ~ 152mV, Ratiometric
Voltage - Supply
15V
Termination Style
Cable with Connector
Operating Temperature
-40°C ~ 125°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1163347
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
PRESSURE SENSOR CHARACTERISTICS (all devices)
Environmental specifications
Compensated temperature range
Operating temperature range
Storage temperature range
Vibration
Shock
Life
Insulation resistance
Maximum ratings
Voltage version “K”
Voltage version “L”
PERFORMANCE CHARACTERISTICS – COMPENSATED SERIES
Characteristic
Zero pressure offset
Pressure non-linearity
Pressure hysteresis
Repeatability
Temp. effect on span
Temp. effect on offset
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
Long-term stability of offset and span
Response time
Common mode voltage (voltage version “K”)
Input resistance (current version “L”)
Input resistance (voltage version “K”)
Output resistance
PRESSURE RANGE SPECIFICATIONS – COMPENSATED SERIES
Catalog Listing
13C 0500P (A,S) (1,4,5,6) (K,L)
13C 1000P (A,S) (1,4,5,6) (K,L)
13C 2000P (A,S) (1,4,5,6) (K,L)
13C 3000P (A,S) (1,4,5,6) (K,L)
13C 5000P (A,S) (1,4,5,6) (K,L)
NOTES
1. Reference conditions (unless otherwise noted): T
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
9. Common mode voltage as measure from output to ground.
2 Honeywell • Sensing and Control
±0.0015 mA.
pressure. FSS is ratiometric to supply voltage.
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
reading.
case.
(6)
(3)
(4)
(4)
(3)
(5)
Pressure range
0 psi to 500 psi
0 psi to 1000 psi
0 psi to 2000 psi
0 psi to 3000 psi
0 psi to 5000 psi
0 °C to 82 °C [32 °F to 180 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
100 G for 11 ms
100 mΩ at 50 Vdc
10 G at 20 Hz to 2000 Hz
1 million cycles min.
Supply voltage V
Supply current I
(9)
A
= 25 °C [77 °F]; Supply V
S
Minimum
-2
0.50
2.0
8.0
3.0
S
= +2.0 mA
= +15 Vdc
Full scale span
98 mV to 102 mV
98 mV to 102 mV
98 mV to 102 mV
98 mV to 102 mV
148 mV to 152 mV
Typical
0
±0.1
±0.015
±0.010
±0.5
±0.5
±0.1
0.1
1.25
4.5
4.5
±0.1
25
(1)
(2)
S
= 10 Vdc ±0.01 Vdc or I
Proof pressure
1500 psi
3000 psi
6000 psi
9000 psi
10,000 psi
Maximum
+2
±0.25
±0.030
±0.030
±1.0
±1.0
±0.3
±0.3
2.0
8.0
50
6.0
13 mm Series
(7)
S
Burst pressure
2500 psi
10,000 psi
10,000 psi
10,000 psi
5000 psi
= 1.5 mA
Units
mV
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
(8)

Related parts for 13C500PA4K