13C500PA4K Honeywell Sensing and Control, 13C500PA4K Datasheet - Page 3

no-image

13C500PA4K

Manufacturer Part Number
13C500PA4K
Description
SENSOR 500PSIA COMP RATIO OUT
Manufacturer
Honeywell Sensing and Control
Series
13 mmr
Datasheet

Specifications of 13C500PA4K

Pressure Type
Absolute
Operating Pressure
500 PSI
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
148 ~ 152mV, Ratiometric
Voltage - Supply
15V
Termination Style
Cable with Connector
Operating Temperature
-40°C ~ 125°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1163347
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
PERFORMANCE CHARACTERISTICS – UNCOMPENSATED SERIES
Characteristic
Zero pressure offset
Pressure non-linearity
Pressure hysteresis
Repeatability
Temp. coefficient of span
(
Temp. coefficient of resistance
(0 °C to 82 °C [32 °F to 180 °F])
Temp. coefficient of offset
(0 °C to 82 °C [32 °F to 180 °F])
Thermal hysteresis
(0 °C to 82 °C [32 °F to 180 °F])
Long-term stability of offset and span
Response time
Input resistance
Output resistance
PRESSURE RANGE SPECIFICATIONS – UNCOMPENSATED SERIES
Catalog Listing
13U 0500P A 0 K
13U 1000P A 0 K
13U 2000P A 0 K
13U 3000P A 0 K
13U 5000P A 0 K
NOTES
1. Reference conditions (unless otherwise noted): T
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
4. The error band resulting from maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
Honeywell • Sensing and Control
0 °C to 82 °C [32 °F to 180 °F])
±0.0015 mA.
pressure. FSS is ratiometric to supply voltage.
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
temperature is varied from 25 °C [77 °F] to any other temperature within the specified range 0 °C to 82 °C [32 °F to
180 °F]. This parameter is not 100 % tested and is guaranteed by process design and tested on a sample basis only.
Temperature coefficient of span is evaluated using a constant current source.
(6)
(3)
(3)
(4)
(4)
(4)
(5)
Pressure range
0 psi to 500 psi
0 psi to 1000 psi
0 psi to 2000 psi
0 psi to 3000 psi
0 psi to 5000 psi
Minimum
-7.5
360
2700
4.0
4.0
A
= 25 °C [77 °F]; Supply V
Full scale span
175 mV to 300 mV
175 mV to 300 mV
175 mV to 300 mV
175 mV to 300 mV
290 mV to 500 mV
Typical
0
±0.1
±0.015
±0.010
720
3420
30
±0.1
±0.1
0.1
4.75
4.75
(2)
S
= 10 Vdc ±0.01 Vdc or I
(1)
Proof pressure
1200 psi
3000 psi
6000 psi
9000 psi
10,000 psi
Maximum
+7.5
±0.25
±0.030
±0.030
1260
4500
±0.3
±0.3
6.0
6.0
13 mm Series
(7)
S
Burst pressure
2400 psi
5000 psi
10,000 psi
10,000 psi
10,000 psi
= 1.5 mA
%FSS
%FSS
%FSS
Unit
mV/V
%FSS
%FSS
ppm/°C
ppm/°C
µV/V/°C
ms
kΩ
kΩ
3
(8)