Page 1
... SPST-NC (Molded lead wire models only) -3: SPST-NO (Molded lead wire models only) 4. Terminals H, HS: Solder terminals (HS for UL and CSA approval) D, DS: PCB terminals (DS for UL and CSA approval) T, TS: Quick-connect terminals (#110) (TS for UL and CSA approval) M, MS:Molded lead wires (MS for UL and CSA approval) D2SW 1 ...
Page 2
... The standard lengths of the molded lead wires (AV0.5f) of models incorporating them are 300 mm. 2. Add “HS,” “DS,” “TS,” or “MS” to the end of the model number for the UL/CSA-approved version. (e.g., D2SW-3H → D2SW-3HS). Consult your OMRON sales representative for details. ...
Page 3
... VAC, 50/60 Hz for 1 min between terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min between current-carry- ing metal parts and ground, and between each termi- nal and non-current-carrying metal parts 2 {approx. 100G} max. 2 {approx. 30G} max. Electrical: 200,000 operations min. D2SW D2SW-01 (30 operations/min) 3 ...
Page 4
... For more information on the minimum applicable load, re- fer to Using Micro Loads on page page 7. Separators (Insulation Sheet) ■ Applicable Thickness (mm) switch SS, D2S, D2SW 0.18 Separator for SS0.18 0.4 Separator for SS0.4 Separator for SS@ Separator Note: The material is EAVTC (Epoxide Alkyd Varnished Tetron Cloth) and can withstand temperatures up to 130° ...
Page 5
... Normally closed terminal 6.4±0.2 (red)* OF 0.59 N {60 gf} RF min. 0. gf} OT min. 1 max. 0 max. 13 8.8±0.8 mm 0.5 6.4±0.2 D2SW 1.8±0.1 3.9 5 ...
Page 6
... D2SW Hinge Lever Models D2SW-3L1@ D2SW-01L1 0.3 Stain- less-steel lever Simulated Roller Lever Models D2SW-3L3@ D2SW-01L3 0.3 Stain- less-steel lever Hinge Roller Lever Models D2SW-3L2@ D2SW-01L2 0.3 Stain- less-steel lever 6 5.9 A 3.6 14 5.9 3.6 15.8 1. 4.8 dia. × 3.2 A Polyacetal roller 5 ...
Page 7
... The equation, λ 0.5×10 indicates that the estimated malfunction rate is less than 1/ 2,000,000 operations with a reliability level of 60%. Operating range for micro load models D2SW-01 Inoperable range D2SW –6 /operations ...