KSZ8841-16MBLI Micrel Inc, KSZ8841-16MBLI Datasheet - Page 40

IC MAC CTRLR 8/16BIT 128LQFP

KSZ8841-16MBLI

Manufacturer Part Number
KSZ8841-16MBLI
Description
IC MAC CTRLR 8/16BIT 128LQFP
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8841-16MBLI

Controller Type
Ethernet Controller, MAC
Interface
Bus
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
*
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8841-16MBLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Table 8 gives the format of the RX byte count field.
EEPROM Interface
It is optional in the KSZ8841M to use an external EEPROM. In the case that an EEPROM is not used, the EEEN pin must
be tied Low or floating.
An external serial EEPROM with a standard microwire bus interface is used for non-volatile storage of information such as
the host MAC address, base address, and default configuration settings. The KSZ8841M can detect if the EEPROM is a
1KB (93C46) or 4KB (93C66) EEPROM device (the 93C46 and the 93C66 are typical EEPROM devices). The EEPROM
is organized as 16-bit mode.
If the EEEN pin is pulled high, then the KSZ8841M performs an automatic read of the external EEPROM words 0H to 6H
after the de-assertion of Reset. The EEPROM values are placed in certain host-accessible registers. EEPROM read/write
functions can also be performed by software read/writes to the EEPCR registers.
The KSZ8841M EEPROM format is given in Table 9.
October 2007
Micrel, Inc.
Bit
1
0
Bit
15-11
10-0
Description
Reserved
RXBC Receive Byte Count
Receive Byte Count up to 1916 bytes
Description
RXRF Receive Runt Frame
When set, it indicates that a frame was damaged by a collision or had a premature termination
before the collision window passed.
Runt frames are passed to the host only if the pass bad frame bit is set.
RXCE Receive CRC Error
When set, it indicates that a CRC error has occurred on the current received frame.
CRC error frames are passed to the host only if the pass bad frame bit is set.
WORD
0H
1H
2H
3H
4H
5H
6H
7H-3FH
15
Base Address
Host MAC Address Byte 2
Host MAC Address Byte 4
Host MAC Address Byte 6
Reserved
Reserved
ConfigParam (see Table 10)
Not used for KSZ8841M (available for user to use)
Table 8. RXQ Receive Packet Byte Count Word
Table 7. RXQ Receive Packet Status Word
Table 9. KSZ8841M EEPROM Format
8
40
7
Host MAC Address Byte 1
Host MAC Address Byte 3
Host MAC Address Byte 5
KSZ8841-16/32 MQL/MVL/MBL
0
M9999-102207-1.6