Industrial Photoelectric Sensors Power + input conn Master 4 cond 2M

E3X-CN21

Manufacturer Part Number
E3X-CN21
Description
Industrial Photoelectric Sensors Power + input conn Master 4 cond 2M
Manufacturer
Omron
Type
Photoelectric Sensorsr
Datasheets

Specifications of E3X-CN21

Features
Control the laser with an Amplifier the same size as a Digital Fiber Amplifier
Light Source
Red LED
Connection
Master Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Optical Communications
Several Amplifiers can be slid together and used in groups.
Do not, however, slide the Amplifiers or attempt to remove any
of the Amplifiers during operation.
Hysteresis Adjustment
The hysteresis setting can be adjusted using the Mobile
Console. Do not, however, set the hysteresis to a value lower
than the factory setting. Using a setting less than the factory
setting may result in incorrect operation.
Amplifiers with Connectors
Mounting Connectors
(1) Insert the Master or Slave Connector into the Amplifier
(2) Join Amplifiers together as required after all the Master
(3) Attach the stickers (provided as accessories) to the sides
Note: Attach the stickers to the sides with grooves.
Removing Connectors
(1) Slide the slave Amplifier(s) for which the Connector is to
(2) After the Amplifier(s) has been separated, press down on
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier may move
during operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the
master Amplifier using a nipper or similar tool.
Mounting
until it clicks into place.
and Slave Connectors have been inserted.
of Master and Slave Connectors that are not connected to
other Connectors.
be removed away from the rest of the group.
the lever on the Connector and remove it. (Do not attempt
to remove Connectors without separating them from other
Amplifiers first.)
http://www.ia.omron.com/
Sticker
Clip
Insert
Press down
Sticker
Remove
Lever
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section
underneath the clip.
(1) Insert the clip to be removed into the slit underneath the
(2) Remove the clip by rotating the Amplifier.
When using the E3X-DA-N with the Mobile Console, mount
the End Plate in the way shown below.
Pull Strengths for Connectors (Including Cables)
E3X-CN11, E3X-CN21, E3X-CN22: 30 N max.
E3X-CN12: 12 N max.
clip on another Amplifier.