Z16FMC28200KITG Zilog, Z16FMC28200KITG Datasheet
Z16FMC28200KITG
Specifications of Z16FMC28200KITG
Related parts for Z16FMC28200KITG
Z16FMC28200KITG Summary of contents
Page 1
... Development Kit Quick Start Guide Introduction This quick start guide describes how to set up Zilog’s ZNEO™ Z16FMC Series Motor Control Development Kit and use it to evaluate your motor control designs and applica- tions. The Z16FMC Series Motor Control Development Kit features a Motor Control Modular Development System (MC MDS) daughter board mounted on a 3-Phase Motor Control Application Board (see Figure 1) ...
Page 2
Table 1. ZDS II System Requirements Recommended Configuration • Windows XP Professional SP3 or later • Pentium IV 2.2GHz processor or higher • 1024MB RAM or higher • 135 MB hard disk space • Super VGA Video Adapter • CD-ROM ...
Page 3
Motor Control Application Board as shown in Figure 2. Figure 1. MC MDS Board Mounted on 3-Phase Motor Control Application Board Step 2. Set Switches For your initial setup, set ...
Page 4
Green wire Figure 2. Z16FMC Series Development Kit Motor and DBG Connections QS007901-1110 Z16FMC Series Motor Control Development Kit White wire Blue wire Quick Start Guide Page ...
Page 5
Step 3. Configure the Universal Power Supply The universal power supply kit features different plug adapters in one box and the power supply in another. The power supply ships with a slide-out plate that must be removed ...
Page 6
... If it does not automatically launch the root of the CD-ROM and dou- ble-click the launch.exe 2. DemoShield provides several installation choices. To install ZDS II right away, select Install Zilog Developer Studio. You can install other software and accompanying documentation later. QS007901-1110 Z16FMC Series Motor Control Development Kit file ...
Page 7
Follow the instructions on the screen to complete the installation. Step 3. Install the Opto-Isolated USB Smart Cable The opto-isolated USB Smart Cable connects the development kit to a high-speed or full- speed USB port on your ZDS II ...
Page 8
... Windows XP Observe the following steps to install the USB Smart Cable for Windows XP systems. 1. Connect the Zilog USB device to the Host PC. The Found New Hardware Wizard should activate automatically after connecting the Zilog USB device for the first time; Select No, not at this time if asked to connect to Windows 2. Select Install from a list or specific location (Advanced) and click Next. ...
Page 9
... Do not apply power to the MC MDS board or application board unless Caution: the USB Smart Cable is connected both to the host PC and to the devel- opment board’s DBG port. 3. Run the ZDS II software. By default, the Zilog Developer Studio II program is located in the Start menu under: Programs ® ZiLOG ZDS II_ZNEO_<version_number> ZDS II_ZNEO_<version_number> ...
Page 10
... Select Open Project from the File menu. The Open Project dialog box appears. 5. Browse to the Samples default in the following filepath: c:\Program Files\ZiLOG\ZDSII_ZNEO_<version_number>\ samples\Z16FMC\Z16FMC_Series 6. Select the Z16FMC_motordemo.zdsproj gram screen opens (see Figure 4). To view the project source files, double-click the Project Files folder on left side of the IDE interface ...
Page 11
... Figure 4. Zilog Developer Studio II Opening Screen 7. Select the correct debug tool using Project Settings Debugger Debug Tool. For example, Select USBSmartCable when using the USB Smart Cable. 8. Click F1 for additional info on how to setup the debugger. 9. Click OK. 10. Click the Rebuild All icon to build the project. Wait for the build to complete as indicated by the Build Complete confirmation in the Status window at the bottom of the screen ...
Page 12
... Figure 5. Option Bits Warning Dialog Box 12. Click Go to start the program. The screen changes as illustrated in Figure 6 on page 12. Figure 6. Zilog Developer Studio II Active Screen QS007901-1110 Z16FMC Series Motor Control Development Kit Quick Start Guide Go Icon Page ...
Page 13
... USB Optoisolator Smart Cable interface is present and selected. If the serial number is missing, reinstall the opto-isolated USB Smart Cable driver software. • In ZDS II, verify that Z16FMC28200KITG is selected as the target. • In ZDS II, navigate to Project Tool selection is USB Smart Cable. ...
Page 14
... Try reloading the sample project as described in 6. If you perform these steps and cannot get the sample code to run, contact Zilog Technical Support at support.zilog.com. QS007901-1110 Z16FMC Series Motor Control Development Kit button. Verify that the project rebuilds with no ...
Page 15
... NOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. Z8, ZNEO and Z16FMC are trademarks or registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. QS007901-1110 ...