G5CA-1A4-DC24 Omron, G5CA-1A4-DC24 Datasheet - Page 2

General Purpose / Industrial Relays Sealed SPST-NO 24VDC

G5CA-1A4-DC24

Manufacturer Part Number
G5CA-1A4-DC24
Description
General Purpose / Industrial Relays Sealed SPST-NO 24VDC
Manufacturer
Omron
Series
G5CAr
Datasheets

Specifications of G5CA-1A4-DC24

Coil Resistance
2880 Ohms
Contact Form
SPST - NO
Coil Voltage
24 VDC
Contact Rating
10 A at 250 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
10 A
Coil Type
Non-Latching
Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Current, Rating
10 A
Function
Power
Mounting Type
PCB
Number Of Pins
4
Power, Rating
2500⁄300 VA⁄W
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Subminiature Dimensions
16 × 22 × 11 mm (L × W × H)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5CA-1A4-DC24V
Quantity:
12 000
Specifications
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
■ Contact Ratings
186
Item
Rated current
Coil resistance
Must-operate voltage
Must-release voltage
Max. voltage
Power consumption
Item
Contact form
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The "maximum voltage" is the maximum voltage that can be applied to the relay coil.
PCB Relay
Standard
Resistive load
Single
Silver alloy
10 A at 250 VAC;
10 A at 30 VDC
10 A
250 VAC, 125 VDC
10 A
2,500 VA, 300 W
G5CA
Standard, high-capacity, or quick-connect terminals High-sensitivity
5 VDC
40 mA
125 Ω
75% of rated voltage (max.)
10% of rated voltage (min.)
150% (standard)/130% (high-capacity, quick-connect
terminals) of rated voltage (at 23°C)
Approx. 200 mW
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
3 A at 250 VAC;
3 A at 30 VDC
750 VA, 90 W
12 VDC
16.7 mA
720 Ω
High-sensitivity
Resistive load
10 A at 250 VAC;
10 A at 30 VDC
10 A
10 A
2,500 VA, 300 W
24 VDC
8.3 mA
2,880 Ω
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
3 A at 250 VAC;
3 A at 30 VDC
750 VA, 90 W
5 VDC
167 Ω
80% of rated voltage (max.)
150% of rated voltage at 23°C
30 mA
Approx. 150 mW
High-capacity, or quick-connect
terminals
Resistive load
15 A at 110 VAC;
10 A at 30 VDC
15 A
15 A
2,500 VA, 300 W
12 VDC
12.5 mA
960 Ω
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
5 A at 110 VAC;
3 A at 30 VDC
750 VA, 90 W
24 VDC
6.25 mA
3,840 Ω