G5CA-1A4-DC24 Omron, G5CA-1A4-DC24 Datasheet - Page 4

General Purpose / Industrial Relays Sealed SPST-NO 24VDC

G5CA-1A4-DC24

Manufacturer Part Number
G5CA-1A4-DC24
Description
General Purpose / Industrial Relays Sealed SPST-NO 24VDC
Manufacturer
Omron
Series
G5CAr
Datasheets

Specifications of G5CA-1A4-DC24

Coil Resistance
2880 Ohms
Contact Form
SPST - NO
Coil Voltage
24 VDC
Contact Rating
10 A at 250 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
10 A
Coil Type
Non-Latching
Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Current, Rating
10 A
Function
Power
Mounting Type
PCB
Number Of Pins
4
Power, Rating
2500⁄300 VA⁄W
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Subminiature Dimensions
16 × 22 × 11 mm (L × W × H)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5CA-1A4-DC24V
Quantity:
12 000
Engineering Data
Dimensions
Note: All units are in millimeters unless otherwise indicated.
188
G5CA-1A(-E)
G5CA-1A4(-H)
Maximum Switching Capacity
Operating Temperature vs.
Must-operate/Must-release Voltage
Note: The "maximum voltage" is the maximum
100
80
60
40
20
0.7
0.5
0.3
0.1
50
30
15
10
0
−40
7
5
3
1
1
AC resistive load
G5CA-1A-E
Sample: G5CA-1A DC
No. of samples: 5
voltage that can be applied to the relay coil,
but, not continously.
DC inductive load
G5CA-1A
G5CA-1A-E
(L/R=7 ms)
DC resistive load
G5CA-1A
G5CA-1A-E
−20
3
5 7 10
PCB Relay
0
AC resistive load
G5CA-1A
AC inductive
load
G5CA-1A
(cos φ=0.4)
11 max.
(10.9)*
3.5
30 50 100
20
1.6
Must-operate voltage
Must-release voltage
Ambient temperature (˚C)
Switching voltage (V)
G5CA
40
10.16
AC inductive
load
G5CA-1A-E
(cos φ=0.4)
22 max.
(21.9)*
300 500 1,000
60
max.
min.
max.
min.
7.62
X
X
80
Electrical Service Life
0.6
500
300
100
70
50
30
10
7
5
3
1
0
0.3
Malfunction Shock
1,000 min.
1,000 min.
2
* Average value
X
Z'
30-VDC resistive load
16 max.
(15.9)*
4
12.7
6
1,000 min.
250-VAC resistive load
8
200
400
600
800
0.4
Y'
Y
110-VAC resistive load
1,000 min.
800
600
400
200
10
Mounting Holes (PCB)
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Switching current (A)
2.54
Two, 1 dia.
elliptic holes
12
Y
Y'
Shock direction
X
Unit: m/s
14
1,000 min.
1,000 min.
2.54
10.16
16
Z
X'
X'
2
17.78
Z
Z'
Ambient Temperature vs.
Maximum Coil Voltage
200
180
160
150
140
130
120
100
80
60
2
0
No. of samples: 10
Measured value: The value at which
Standard:
Two, 1 dia. hole
20
12.7
30
Continuous max.
permissile voltage (15 A)
Note: Orientation marks are
Terminal Arrangement/
Internal Connections
40
(BOTTOM VIEW)
indicated as follows:
Continuous max.
permissile voltage (10 A)
(No coil polarity)
malfunction occurs
in the contact when
the contact is
subjected to shock
three times each in
six directions for
three axes.
200 m/s
50
1
4
Ambient temperature (˚C)
60
2
3
70
2
80
90