PSC-60A Mean Well, PSC-60A Datasheet

Linear & Switching Power Supplies 13.8@2.8, 13.8V@1.5A 59.3W W/Batt Charger

PSC-60A

Manufacturer Part Number
PSC-60A
Description
Linear & Switching Power Supplies 13.8@2.8, 13.8V@1.5A 59.3W W/Batt Charger
Manufacturer
Mean Well
Datasheet

Specifications of PSC-60A

Product
Switching
Commercial/medical
Commercial
Output Power Rating
39 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
2
Output Voltage (channel 1)
13.8 V
Output Current (channel 1)
2.8 A
Output Voltage (channel 2)
13.8 V
Output Current (channel 2)
1.5 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
BATTERY CUT OFF
AC OK
BATTERY LOW
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
60W Single Output with Battery Charger(UPS Function)
Note.3
Note.5
Note.2
PSC-60A
CH1
13.8V
2.8A
0 ~ 4.3A
59.34W
120mVp-p
CH1: 12 ~ 15V
800ms, 50ms/230VAC
50ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
1.6A/115VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
10.5 0.5V
TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC
TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC
Battery low voltage : < 11V
-20 ~ +70
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
589.7K hrs min.
PCB:101.6*50.8*29mm (L*W*H) ; with optional CASE:103.4*62*37mm (L*W*H)
PCB:0.13Kg; 96pcs/13.5Kg/0.89CUFT ; with optional CASE:0.29Kg; 45pcs/14Kg/0.67CUFT
84%
COLD START 30A/115VAC
<1mA / 240VAC
1.0%
0.5%
0.5%
0.03%/
(0~50 ) on CH1 output
(Refer to output load derating curve)
I/P-FG:1.5KVAC
127 ~ 370VDC
1A/230VAC
MIL-HDBK-217F (25 )
10ms/115VAC at full load
1600ms, 50ms/115VAC at full load
CH2
13.8V
1.5A
--------
--------
--------
--------
--------
60A/230VAC
O/P-FG:0.5KVAC
PSC-60B
CH1
27.6V
1.4A
0 ~ 2.15A
59.34W
240mVp-p
CH1: 24 ~ 29V
84%
CH1:28.98 ~ 37.26V
21 1V
Battery low voltage : < 22V
1.0%
0.5%
0.5%
P S C - 6 0
File Name:PSC-60-SPEC 2011-03-03
CH2
27.6V
0.75A
--------
--------
--------
--------
--------
s e r i e s

Related parts for PSC-60A

PSC-60A Summary of contents

Page 1

... Single Output with Battery Charger(UPS Function) SPECIFICATION MODEL PSC-60A OUTPUT NUMBER CH1 DC VOLTAGE 13.8V RATED CURRENT 2.8A CURRENT RANGE 0 ~ 4.3A RATED POWER 59.34W RIPPLE & NOISE (max.) 120mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE CH1 15V VOLTAGE TOLERANCE 1.0% Note.3 LINE REGULATION ...

Page 2

... Mating Housing Terminal JST VHR JST SVH-21T-P1.1 or equivalent or equivalent POWER SWITCHING CONTROL O.L. Mylar film ALARM CIRCUIT RECTIFIERS & FILTER DETECTION CIRCUIT Battery Charger & O.V.P. Back Up Control File Name:PSC-60-SPEC 2011-03- Unit:mm Unit:mm Optional cover: No.998A - Bat. Low +V -V Bat. + Bat. - ...

Page 3

... 100 115 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz Load AC OK (Battery low) R Pin6 DC output com External voltage and R (The max. Sink is 30mA and 50V) Fig 2.2 Internal circuit (Battery Low) File Name:PSC-60-SPEC 2011-03- Ta=25 240 264 V ...

Related keywords