MSO3014 Tektronix, MSO3014 Datasheet

Benchtop Oscilloscopes 100MHZ, 2.5GS/S 4+16 CHANNELS

MSO3014

Manufacturer Part Number
MSO3014
Description
Benchtop Oscilloscopes 100MHZ, 2.5GS/S 4+16 CHANNELS
Manufacturer
Tektronix
Type
Mixed Signalr
Datasheet

Specifications of MSO3014

Equipment Type
Oscilloscope
Sampling Rate
2.5 GS/s
Bandwidth
100 MHz
Display Type
WVGA Color 9 in
Brand/series
MSO3000 Series
Configuration
Bench/Portable
Memory
5 Mpts
Number Of Channels
4 Analog + 16 Digital
Sample Rate
2.5 GS/s analog, 500 MS/s dogtial main, 8.25 GS/s digital MagniVu
Record Length
5 M Points
Input Impedence
50Ω, 75Ω, 1MΩ
Waveform Capture Rate
50,000 wfm/s
Power Analysis
Optional
Standard I/o
(2) USB Host, USB Device, LAN, Video
Display
9.0 inch WVGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Digital Phosphor Oscilloscopes
MSO3000 Series, DPO3000 Series Data Sheet
Features & Benefits
Key Performance Specifications
Ease of Use Features
500, 300, 100 MHz Bandwidth Models
2 and 4 Analog Channel Models
16 Digital Channels (MSO Series)
2.5 GS/s Sample Rate on All Channels
5 Megapoint Record Length on All Channels
>50,000 wfm/s Maximum Waveform Capture Rate
Suite of Advanced Triggers
Wave Inspector
Search of Waveform Data
29 Automated Measurements, and FFT Analysis for Simplified
Waveform Analysis
TekVPI
Probes for Automatic Scaling and Units
9 in. (229 mm) WVGA Widescreen Color Display
Small Footprint and Lightweight – Only 5.8 in. (147 mm) deep and 9 lb.
(4 kg)
®
Probe Interface Supports Active, Differential, and Current
®
Controls Provide Easy Navigation and Automated
Connectivity
Optional Serial Triggering and Analysis
Mixed Signal Design and Analysis (MSO Series)
Optional Application Support
Feature-rich Tools for Debugging Mixed
Signal Designs
With the MSO/DPO3000 Oscilloscope Series, you can visualize analog,
digital, and serial signals with a single instrument to quickly find and
diagnose problems in complex embedded system designs. Bandwidths up
to 500 MHz and a minimum of 5x oversampling on all channels provides
the performance needed for many of today’s mainstream applications. A
deep record length of up to 5 Mpoints is standard on all channels, enabling
you to capture long windows of signal activity while maintaining fine timing
resolution.
With Digital Phosphor technology for fast visualization of signal anomalies,
Wave Inspector
serial bus and power analysis, the MSO/DPO3000 Oscilloscope Series from
Tektronix provides the feature-rich tools you need to simplify and speed
debug of your complex design.
USB 2.0 Host Port on both the Front Panel and Rear Panel for Quick and
Easy Data Storage, Printing, and Connecting a USB Keyboard
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or
Direct Printing to a PictBridge
Integrated 10/100 Ethernet Port for Network Connection and Video Out
Port to Export the Oscilloscope Display to a Monitor or Projector
Automated Serial Triggering, Decode, and Search Options for I
CAN, LIN, RS-232/422/485/UART, and I
Automated Triggering, Decode, and Search on Parallel Buses
Multichannel Setup and Hold Triggering
MagniVu™ High-speed Acquisition Provides 121.2 ps Fine Timing
Resolution on Digital Channels
Power Analysis
HDTV and Custom Video Analysis
®
controls for rapid waveform navigation, and automated
®
-compatible Printer
2
S/LJ/RJ/TDM
2
C, SPI,

MSO3014 Summary of contents

Page 1

... With Digital Phosphor technology for fast visualization of signal anomalies, Wave Inspector controls for rapid waveform navigation, and automated ® serial bus and power analysis, the MSO/DPO3000 Oscilloscope Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design. C, SPI, 2 ...

Page 2

... Capture – Triggering on a specific transmit data packet going across an RS-232 bus. A complete set of triggers, including triggers for specific serial packet content, ensures you quickly capture your event of interest ...

Page 3

... For extended analysis, National Instrument’s LabVIEW SignalExpress™ Tektronix Edition provides over 200 built-in functions including time and frequency domain analysis, limit testing, data logging, and customizable reports. ...

Page 4

... Once again, turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way. 4 www.tektronix.com Search step 1: You define what you would like to find. Search step 2: Wave Inspector automatically searches through the record and marks each event with a hollow white triangle ...

Page 5

... One common problem shared by both logic analyzers and mixed-signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display. The MSO3000 Series has color-coded digital traces, displaying ones in green and zeros in blue. www.tektronix.com 5 ...

Page 6

... USB keyboard. By simply placing digital waveforms next to each other, they form a group. 6 www.tektronix.com The P6316 MSO probe offers two eight-channel pods to simplify connecting to your device. Once a group is formed, you can position all the channels contained in that group collectively ...

Page 7

... MSO/DPO3000 Series, you can have the oscilloscope automatically search through the acquired data for user-defined criteria including serial packet content. Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Previous (←) and Next (→) buttons on the front panel. S/LJ/RJ/TDM 2 www.tektronix.com 7 ...

Page 8

... PC or complex software setup is required. 8 www.tektronix.com Viewing an NTSC video signal. Notice the intensity-graded view provided by the DPO’s ability to represent time, amplitude, and distribution of amplitude over time. Video Design and Development ...

Page 9

... The TekVPI interface enables direct attachment of current probes without requiring a separate power supply. TekVPI probes can be controlled remotely through USB, GPIB, or Ethernet, enabling more versatile solutions in ATE environments. www.tektronix.com 9 ...

Page 10

... Data Sheet NI LabVIEW SignalExpress™ Tektronix Edition is a fully interactive measurement acquisition and analysis software developed jointly with National Instruments and optimized for the MSO/DPO Series. Extended Analysis Acquiring data and measurements from the MSO/DPO3000 Series is as simple as connecting a USB cable from the oscilloscope to your PC. Key software applications - NI LabVIEW SignalExpress™ ...

Page 11

... Minimum Voltage Swing 500 mV pk-pk Input Impedance 101 kΩ Probe Loading 8 pF Vertical Resolution 1 bit Digital Phosphor Oscilloscopes — MSO3000 Series, DPO3000 Series MSO3012 MSO3014 DPO3012 DPO3014 2 4 100 MHz 100 MHz 3 MHz AC, DC, GND 1 MΩ ±1%, 75 Ω ±1%, 50 Ω ±1% ...

Page 12

... Mb/s (by LIN definition, 20 kb/s). Parallel (available Trigger on a parallel bus data value. Parallel bus can be from bits in size. Binary and Hex radices are supported. on MSO models only) 12 www.tektronix.com Trigger Sensitivity Characteristic Description Internal DC Coupled 0.5 div from MHz, increasing to 1 div at ...

Page 13

... Digital Phosphor Oscilloscopes — MSO3000 Series, DPO3000 Series Waveform Math Characteristic Arithmetic Math Functions FFT Advanced Math Software Product NI LabVIEW SignalExpress™ Tektronix Edition OpenChoice ® Desktop , I , True RMS Crest Factor IVI Driver eScope Description Add, subtract, multiply, and divide waveforms. ...

Page 14

... Power Consumption 120 W maximum Optional TekVPI ® Output Voltage External Power Output Current Supply* Power Consumption Required when total oscilloscope probe power usage exceeds www.tektronix.com Physical Characteristics Dimensions Height Width Depth Weight Net Shipping Rackmount Configuration Cooling Clearance Environmental Characteristic Temperature ...

Page 15

... MSO3000 Models Product Description MSO3012 100 MHz, 2.5 GS/s, 5M record length, 2+16 channel mixed-signal oscilloscope MSO3014 100 MHz, 2.5 GS/s, 5M record length, 4+16 channel mixed-signal oscilloscope MSO3032 300 MHz, 2.5 GS/s, 5M record length, 2+16 channel mixed-signal oscilloscope MSO3034 300 MHz, 2 ...

Page 16

... Required when total oscilloscope probe power usage exceeds 20 W. Power cord not included. 5 Warranty Three-year warranty covering all parts and labor, excluding probes. Product(s) are manufactured in ISO registered facilities. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. ...

Page 17

... Digital Phosphor Oscilloscopes — MSO3000 Series, DPO3000 Series www.tektronix.com 17 ...

Page 18

... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...