MSO3014 Tektronix, MSO3014 Datasheet - Page 2

Benchtop Oscilloscopes 100MHZ, 2.5GS/S 4+16 CHANNELS

MSO3014

Manufacturer Part Number
MSO3014
Description
Benchtop Oscilloscopes 100MHZ, 2.5GS/S 4+16 CHANNELS
Manufacturer
Tektronix
Type
Mixed Signalr
Datasheet

Specifications of MSO3014

Equipment Type
Oscilloscope
Sampling Rate
2.5 GS/s
Bandwidth
100 MHz
Display Type
WVGA Color 9 in
Brand/series
MSO3000 Series
Configuration
Bench/Portable
Memory
5 Mpts
Number Of Channels
4 Analog + 16 Digital
Sample Rate
2.5 GS/s analog, 500 MS/s dogtial main, 8.25 GS/s digital MagniVu
Record Length
5 M Points
Input Impedence
50Ω, 75Ω, 1MΩ
Waveform Capture Rate
50,000 wfm/s
Power Analysis
Optional
Standard I/o
(2) USB Host, USB Device, LAN, Video
Display
9.0 inch WVGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Sheet
Discover – Fast waveform capture rate - over 50,000 wfm/s - maximizes the probability
of capturing elusive glitches and other infrequent events.
Comprehensive Features Speed Every Stage
of Debug
The MSO/DPO3000 Series offers a robust set of features to speed every
stage of debugging your design – from quickly discovering an anomaly and
capturing it, to searching your waveform record for the event and analyzing
its characteristics and your device’s behavior.
Discover
To debug a design problem, first you must know it exists. Every
design engineer spends time looking for problems in their design, a
time-consuming and frustrating task without the right debug tools.
The MSO/DPO3000 Series offers the industry’s most complete visualization
of signals, providing fast insight into the real operation of your device. A
fast waveform capture rate - greater than 50,000 waveforms per second -
enables you to see glitches and other infrequent transients within seconds,
revealing the true nature of device faults. A digital phosphor display with
intensity grading shows the history of a signal’s activity by intensifying areas
of the signal that occur more frequently, providing a visual display of just
how often anomalies occur.
2
www.tektronix.com
Capture – Triggering on a specific transmit data packet going across an RS-232 bus. A
complete set of triggers, including triggers for specific serial packet content, ensures you
quickly capture your event of interest.
Capture
Discovering a device fault is only the first step. Next, you must capture the
event of interest to identify root cause.
The MSO/DPO3000 Series provides a complete set of triggers - including
runt, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel
data - to help quickly find your event. With up to a 5 Mpoint record length,
you can capture many events of interest, even thousands of serial packets,
in a single acquisition for further analysis while maintaining high resolution
to zoom in on fine signal details.
From triggering on specific packet content to automatic decode in multiple
data formats, the MSO/DPO3000 Series provides integrated support
for the industry’s broadest range of serial buses – I
RS-232/422/485/UART, and I
two serial and/or parallel buses simultaneously means you gain insight into
system-level problems quickly.
To further help troubleshoot system-level interactions in complex embedded
systems, the MSO3000 Series offers 16 digital channels in addition to
its analog channels. Since the digital channels are fully integrated into
the oscilloscope, you can trigger across all input channels, automatically
time-correlating all analog, digital, and serial signals. The MagniVu™
high-speed acquisition enables you to acquire fine signal detail (up to
121.2 ps resolution) around the trigger point for precision measurements.
MagniVu is essential for making accurate timing measurements for
setup and hold measurements, clock delay, signal skew, and glitch
characterization.
2
S/LJ/RJ/TDM. The ability to decode up to
2
C, SPI, CAN, LIN,