G1G120-AB67-02 EBM-Papst Industries Inc, G1G120-AB67-02 Datasheet

BLOWER CENT 143X40MM 24VDC

G1G120-AB67-02

Manufacturer Part Number
G1G120-AB67-02
Description
BLOWER CENT 143X40MM 24VDC
Manufacturer
EBM-Papst Industries Inc
Series
ECr
Type
Scrollr

Specifications of G1G120-AB67-02

Bearing Type
Ball
Voltage - Rated
24VDC
Weight
3.5 lbs (1.6kg)
Current Rating
1.90A
Voltage Range
16 ~ 28VDC
Operating Temperature
-13 ~ 140°F (-25 ~ 60°C)
Fan Type
Blower
Size / Dimension
Rectangular/Rounded - 178mm L x 184mm H x 115mm W (132mm Dia)
Power (watts)
40.0W
Features
PWM Control; Speed Sensor (Tach)
Rpm
2200 RPM
Termination
4 Wire Leads
External Depth
115mm
External Diameter
120mm
Current Type
DC
Supply Voltage
24VDC
Flow Rate
255CFM
Noise Rating
62dBA
Diameter
120mm
Rotational Speed Max
2200rpm
Air Flow
150 CFM
Brand/series
G1G120
Dimensions
120 mm
Noise Level
62 dBA
Power, Rating
40 W
Voltage, Rating
24 VDC
Technical Features
Control Input 0-10 VDC/PWM, Tach Output
Direction Of Rotation
Clockwise, Seen on Rotor
Type Of Protection
IP 20
Approvals
UL 1004, CSA C22.2 No. 100 Tested with UL
Flow Rate - Imperial
255CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Noise
-
Static Pressure
-
Air Flow
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
381-2398
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone: +49(0)7938/81-0
Fax: +49(0)7938/81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES
1.1 Levels of hazard warnings
1.2 Staff qualification
1.3 Basic safety rules
1.4 Electrical voltage
1.5 Safety and protective functions
1.6 Electromagnetic radiation
1.7 Mechanical movement
1.8 Emission
1.9 Hot surface
1.10 Transport
1.11 Storage
1.12 Disposal
2. PROPER USE
3. TECHNICAL DATA
3.1 Graphic rendition of products
3.2 Nominal data
3.3 Technical description
3.4 Mounting data
3.5 Storage conditions
3.6 Electromagnetic compatibility
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.3 Connection of the cables
4.4 Connection diagram
4.5 Checking the connections
4.6 Switch on device
4.7 Switching off the device
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
5.1 Cleaning
5.2 Safety test
Item no.: 50907-5-9970 · Revision status: KM70681 · Print-out on 20/10/2010 · Created by A. Kehm (VM---) · Page 1 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
G1G120-AB67-02
Operating instructions
1
1
1
1
1
2
2
2
2
2
2
2
2
3
4
4
5
5
5
5
5
6
6
6
6
7
8
8
8
8
9
9
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
1.2 Staff qualification
Only specialised electrical personnel may install the device, perform the
test run and work on the electrical system.
Only trained and authorised specialist personnel are permitted to
transport, unpack, assemble, operate or maintain the device, or to use it
in any other manner.
1.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
Observe the following when working on the unit:
1.4 Electrical voltage
Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
Check the electrical equipment of the device at regular intervals.
Remove loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
Keep out of the danger zone of the device.
When working on the device, switch off the mains

Related parts for G1G120-AB67-02

G1G120-AB67-02 Summary of contents

Page 1

... G1G120-AB67-02 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone: +49(0)7938/81-0 Fax: +49(0)7938/81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND NOTES 1.1 Levels of hazard warnings 1.2 Staff qualification 1.3 Basic safety rules 1.4 Electrical voltage 1.5 Safety and protective functions 1.6 Electromagnetic radiation 1 ...

Page 2

... G1G120-AB67-02 supply voltage and secure the latter from being switched on again. Wait until the device stops. 1.5 Safety and protective functions DANGER Missing safety device and non-functioning safety device If there is no safety device, you could be seriously injured, for example by reaching into the running device with your hands. ...

Page 3

... G1G120-AB67-02 2. PROPER USE The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur. ...

Page 4

... G1G120-AB67-02 3. TECHNICAL DATA 3.1 Graphic rendition of products All measures have the unit mm. 1 Connection line AWG20, 4x brass lead tips crimped Item no.: 50907-5-9970 · Revision status: KM70681 · Print-out on 20/10/2010 · Created by A. Kehm (VM---) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com ...

Page 5

... G1G120-AB67-02 3.2 Nominal data Motor M1G055-BD Nominal voltage [VDC] 24 Nominal voltage range [VDC] Type of data definition rfa -1 Speed [min ] 2200 Power input [W] 40 Current draw [A] 1.9 Min. ambient - 25 temperature [°C] Max. ambient +60 temperature [° max. load · max. efficiency · rfa = running at free air cs = customer specs · ...

Page 6

... G1G120-AB67-02 4. CONNECTION AND START-UP 4.1 Connecting the mechanical system CAUTION Cutting and crushing hazard when removing the blower from the packaging Carefully lift the blower out of its packaging, only touching the housing. Make sure to avoid any shock. Wear safety shoes and cut-resistant safety gloves. ...

Page 7

... G1G120-AB67-02 4.4 Connection diagram Line No. Signal Colour 1 1 GND blue 1 2 DUE white 1 3 0-10 VDC yellow +24 VDC red Item no.: 50907-5-9970 · Revision status: KM70681 · Print-out on 20/10/2010 · Created by A. Kehm (VM---) · Page ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com ...

Page 8

... G1G120-AB67-02 4.5 Checking the connections Make sure that the power is off (all phases). Secure it from being switched on again. Check the correct fit of the connection lines. 4.6 Switch on device WARNING Hot motor housing Fire hazard Ensure that no combustible or flammable materials are located close to the blower. ...

Page 9

... G1G120-AB67-02 If you have any other problems, contact ebm-papst. 5.1 Cleaning NOTE Damage to the device during cleaning. Malfunction possible Do not clean the device using a water jet or high-pressure washer. Do not use any cleaners containing acids, bases or solvents. 5.2 Safety test What has to be ...