G1G120-AB67-02 EBM-Papst Industries Inc, G1G120-AB67-02 Datasheet - Page 8

BLOWER CENT 143X40MM 24VDC

G1G120-AB67-02

Manufacturer Part Number
G1G120-AB67-02
Description
BLOWER CENT 143X40MM 24VDC
Manufacturer
EBM-Papst Industries Inc
Series
ECr
Type
Scrollr

Specifications of G1G120-AB67-02

Bearing Type
Ball
Voltage - Rated
24VDC
Weight
3.5 lbs (1.6kg)
Current Rating
1.90A
Voltage Range
16 ~ 28VDC
Operating Temperature
-13 ~ 140°F (-25 ~ 60°C)
Fan Type
Blower
Size / Dimension
Rectangular/Rounded - 178mm L x 184mm H x 115mm W (132mm Dia)
Power (watts)
40.0W
Features
PWM Control; Speed Sensor (Tach)
Rpm
2200 RPM
Termination
4 Wire Leads
External Depth
115mm
External Diameter
120mm
Current Type
DC
Supply Voltage
24VDC
Flow Rate
255CFM
Noise Rating
62dBA
Diameter
120mm
Rotational Speed Max
2200rpm
Air Flow
150 CFM
Brand/series
G1G120
Dimensions
120 mm
Noise Level
62 dBA
Power, Rating
40 W
Voltage, Rating
24 VDC
Technical Features
Control Input 0-10 VDC/PWM, Tach Output
Direction Of Rotation
Clockwise, Seen on Rotor
Type Of Protection
IP 20
Approvals
UL 1004, CSA C22.2 No. 100 Tested with UL
Flow Rate - Imperial
255CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Noise
-
Static Pressure
-
Air Flow
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
381-2398
4.5 Checking the connections
4.6 Switch on device
Inspect the device for visible external damage and the proper function of
the protective features before switching it on.
4.7 Switching off the device
Item no.: 50907-5-9970 · Revision status: KM70681 · Print-out on 20/10/2010 · Created by A. Kehm (VM---) · Page 8 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
G1G120-AB67-02
Make sure that the power is off (all phases).
Secure it from being switched on again.
Check the correct fit of the connection lines.
Apply the nominal voltage to the voltage supply.
Start the device by changing the input signal.
Disconnect the device from the supply voltage.
WARNING
Hot motor housing
Fire hazard
Ensure that no combustible or flammable materials are
located close to the blower.
Operating instructions
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Return the device to ebm-
papst for repair or replacement.
Malfunction/error
Motor does not turn
Impeller running
roughly
Overtemperature of
electronics/motor
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
If the device remains out of use for some time, e.g. when in
storage, we recommend switching the device on for at least 2
hours to allow any condensate to evaporate and to move the
bearings.
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
Keep out of the danger zone of the device.
When working on the device, switch off the mains
supply voltage and secure the latter from being switched on
again.
Wait until the device stops.
Possible cause
Mechanical blockage
Mains supply voltage
faulty
Faulty connection
Imbalance in rotating
parts
Insufficient cooling
Ambient temperature
too high
Unacceptable
operating point
Possible remedy
Switch off, de-
energise, and remove
mechanical blockage
Check mains supply
voltage, restore power
supply
apply control signal
Correct connection,
see connection diagram
Clean the device, if
imbalance still evident
after cleaning, replace
device
Improve cooling if
possible.
Reset by switching
off the mains supply
voltage for at least 20
s after motor standstill
Lower ambient
temperature if
possible.
Reset by reducing
control input to 0.
Check operating point

Related parts for G1G120-AB67-02