PT7C4311WEX Pericom Semiconductor, PT7C4311WEX Datasheet - Page 10

IC REAL TIME CLK/CALENDAR 8-SOIC

PT7C4311WEX

Manufacturer Part Number
PT7C4311WEX
Description
IC REAL TIME CLK/CALENDAR 8-SOIC
Manufacturer
Pericom Semiconductor
Type
Clock/Calendarr
Datasheet

Specifications of PT7C4311WEX

Memory Size
56B
Time Format
Binary
Date Format
Binary
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.2 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PT7C4311WEXTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PT7C4311WEX
Manufacturer:
Pericom
Quantity:
2 400
Part Number:
PT7C4311WEX
Manufacturer:
PERICOM
Quantity:
20 000
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
When transferring data, the receiver generates a confirmation response (ACK signal, low active) each time an 8-bit data segment
is received. If there is no ACK signal from the receiver, it indicates that normal communication has not been established. (This
does not include instances where the master device intentionally does not generate an ACK signal.)
Immediately after the falling edge of the clock pulse corresponding to the 8th bit of data on the SCL line, the transmitter releases
the SDA line and the receiver sets the SDA line to low (= acknowledge) level.
After transmitting the ACK signal, if the Master remains the receiver for transfer of the next byte, the SDA is released at the
falling edge of the clock corresponding to the 9th bit of data on the SCL line. Data transfer resumes when the Master becomes the
transmitter.
When the Master is the receiver, if the Master does not send an ACK signal in response to the last byte sent from the slave, that
indicates to the transmitter that data transfer has ended. At that point, the transmitter continues to release the SDA and awaits a
STOP condition from the Master.
e)
The I
slave addresses are allocated to each device.
All communications begin with transmitting the [START condition] + [slave address (+ R/W specification)]. The receiving device
responds to this communication only when the specified slave address it has received matches its own slave address.
Slave addresses have a fixed length of 7 bits. See table for the details.
An R/W bit is added to each 7-bit slave address during 8-bit transfers.
2. I
PT0322(08/09)
Operation
Data acknowledge response (ACK signal)
Slave Address
2
Write
C bus device does not include a chip select pin such as is found in ordinary logic devices. Instead of using a chip select pin,
Read
2
C Bus’s Basic Transfer Format
SDA from transmitter
SCL from Master
SDA from receiver
(sending side)
(receiving side)
Transfer data
Sr
D1 h
D0 h
S
Start indication
Restart indication
1
bit 7
1
bit 6
1
2
P
bit 5
Stop indication
0
Slave address
10
bit 4
1
bit 3
A
A
0
Real-time Clock Module (I
RTC Acknowledge
Master Acknowledge
8
bit 2
0
bit 1
0
Release SDA
ACK signal
Low active
9
0 (= Write)
1 (= Read)
Data Sheet
R / W bit
PT7C4311
bit 0
2
C Bus)
Ver: 2