SI3482-A01-GM Silicon Laboratories Inc, SI3482-A01-GM Datasheet - Page 21

no-image

SI3482-A01-GM

Manufacturer Part Number
SI3482-A01-GM
Description
IC CTLR POE 24-48PORT PSE 24-QFN
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI3482-A01-GM

Applications
Power Over Ethernet Controller
Current - Supply
12.1mA
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-WFQFN Exposed Pad
Product
Power Distribution
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3482-A01-GMR
Manufacturer:
LT
Quantity:
124
Part Number:
SI3482-A01-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Table 13 lists the Port Priority Status values.
The priority status of a port is the currently-active priority and may be different than the configured priority of the
port. If a port is forced on or off and the configured priority is low or high, the priority status is elevated to the forced
priority. If a forced port is returned to automatic control, the Power Manager returns the priority status to the
configured priority.
4.3.5. GetPortPowerConsumed
Get the power that a PD is currently using.
Prototype:
Parameters:
Return Value:
4.3.6. GetPortPowerGranted
Get the power that is allocated to a PD.
Prototype:
Parameters:
Return Value:
4.3.7. GetPortPowerRequested
Get the power that a PD says it needs.
Prototype:
Parameters:
Return Value:
4.3.8. GetPortPowerAvailable
Get the maximum request that would be successfully granted.
Prototype:
Parameters:
Return Value:
An LLDP agent calls this routine to ask the question, “What is the maximum power that you would give me if I
asked for it?”
If a port has a power limit, then the power limit is returned. If a port does not have a power limit and the port can
supply high power, then maximum power (40 W) is returned; otherwise, low power (15.4 W) is returned.
Port Priority Status
INT32 GetPortPowerGranted ( UINT8 Port )
Port
Port power granted in milliwatts or an error code.
INT32 GetPortPowerRequested ( UINT8 Port )
Port
Port power requested in milliwatts or an error code.
INT32 GetPortPowerAvailable ( UINT8 Port )
Port
Port power available in milliwatts or an error code.
INT32 GetPortPowerConsumed ( UINT8 Port )
Port
Port power consumed in milliwatts or an error code.
Forced
Critical
High
Low
The port number (1–48)
The port number (1–48)
The port number (1–48)
The port number (1–48)
Table 13. Port Priority Status Values
Rev. 0.1
Value
0
1
2
3
PRIORITY_CRITICAL
PRIORITY_FORCED
PRIORITY_HIGH
PRIORITY_LOW
Symbol
Si3482
21