SE95U,025 NXP Semiconductors, SE95U,025 Datasheet - Page 8

no-image

SE95U,025

Manufacturer Part Number
SE95U,025
Description
IC TEMP SENSOR DGTL
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SE95U,025

Function
Temp Sensor, Watchdog
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
2.8 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
Die
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
NXP Semiconductors
SE95_7
Product data sheet
8.2 Register list
8.3 Register pointer
false alert if the address 0Ch is sent and cannot be active on the I
used. Consider using the SE98 since it supports SMBus ARA as well as time-out features
and provides 1 C accuracy.
Table 4.
The SE95 contains 7 data registers. The registers can be 1 byte or 2 bytes wide, and are
defined in
register during I
and reserved for manufacturer use. Note that when reading a two-byte register, the host
must provide enough clock pulses as required by the I
for the device to completely return both data bytes. Otherwise the device may hold the
SDA line in LOW state, resulting in a bus hang condition.
Table 5.
The register pointer or pointer byte is an 8-bit data byte that is equivalent to the register
command in the I
accessed for a write or read operation. Its values are listed as pointer values in
For the device register I
be included within the command as illustrated in the I
Section
The command statements for writing data to a register must always include the pointer
byte; while the command statements for reading data from a register may or may not
include it. To read a register that is different from the one that has been recently read, the
pointer byte must be included. However, to re-read a register that has been recently read,
the pointer byte may not have to be included in the reading.
Register
name
Conf
Temp
Tos
Thyst
ID
Reserved
Reserved
MSB
1
8.7.
Table
Address table
Register table
Pointer
value
01h
00h
03h
02h
05h
04h
06h
Ultra high accuracy digital temperature sensor and thermal watchdog
2
5. The registers are accessed by the value in the content of the pointer
C-bus communication. The types of registers are: read only, read/write,
2
0
C-bus definitions and is used to identify the device register to be
R/W
R/W
read
only
R/W
R/W
read
only
N/A
N/A
Rev. 07 — 2 September 2009
2
C-bus communication, the pointer byte may or may not need to
POR
state
00h
N/A
5000h
4B00h
A1h
N/A
N/A
0
Description
configuration register: contains a single 8-bit data byte;
to set an operating condition
temperature register: contains two 8-bit data bytes; to
store the measured Temp
overtemperature shutdown threshold register: contains
two 8-bit data bytes; to store the overtemperature
shutdown limit; default T
hysteresis register: contains two 8-bit data bytes; to
store the hysteresis limit; bit 7 to bit 0 are also used in
OTP (One Time Programmable) test mode to supply
OTP write data; default T
identification register: contains a single 8-bit data byte
for the manufacturer ID code
reserved
reserved
1
2
2
C-bus protocol figures in
C-bus protocol (see
A2
os
hyst
= 80 C
= 75 C
2
C-bus if this address is
A1
© NXP B.V. 2009. All rights reserved.
Section
SE95
Table
LSB
A0
8.7)
8 of 27
5.

Related parts for SE95U,025