STLM75M2E STMicroelectronics, STLM75M2E Datasheet - Page 17

IC TEMP SENSOR DIGITAL SO-8

STLM75M2E

Manufacturer Part Number
STLM75M2E
Description
IC TEMP SENSOR DIGITAL SO-8
Manufacturer
STMicroelectronics
Datasheet

Specifications of STLM75M2E

Featured Product
STM32 Cortex-M3 Companion Products
Function
Temp Sensor, Watchdog
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire, I2C)
Digital Output - Number Of Bits
9 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Ic Output Type
Digital
Sensing Accuracy Range
± 0.5°C
Temperature Sensing Range
-55°C To +125°C
Supply Current
125µA
Supply Voltage Range
2.7V To 5.5V
Sensor Case Style
SOIC
No. Of Pins
8
Rohs Compliant
Yes
For Use With
497-10508 - BOARD EVAL FOR MEMS SENSORS497-10048 - BOARD EVAL ACCELEROMETER497-6238 - BOARD STLM75/STDS75/ST72F651
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STLM75M2E
Manufacturer:
AT&T
Quantity:
6 218
Part Number:
STLM75M2E
Manufacturer:
ST
0
Part Number:
STLM75M2E
Manufacturer:
ST
Quantity:
20 000
STLM75
Table 5.
3.1.2
Table 6.
1. Indicates operation mode; 0 = comparator mode, and 1 = interrupt mode (see
2. The OS is active-low ('0').
Pointer
STLM75
value
Default
page
(H)
Byte
00
01
02
03
Keys: SD = shutdown control bit
13).
P1
0
0
1
1
M = thermostat mode
POL = output polarity
FT0 = fault tolerance0 bit
Register pointers selection summary
Configuration register
The configuration register is used to store the device settings such as device operation
mode, OS operation mode, OS polarity, and OS fault queue.
The configuration register allows the user to program various options such as thermostat
fault tolerance, thermostat polarity, thermostat operating mode, and shutdown mode. The
user has READ/WRITE access to all of the bits in the configuration register except the MSB
(Bit7), which is reserved as a “Read only” bit (see
thus powers-up in its default state only.
Configuration register format
Reserved
MSB
Bit7
P0
0
1
0
1
0
TEMP
CONF
Name
T
T
HYS
OS
Bit6
Overtemperature
0
0
Configuration
Temperature
Description
Hysteresis
shutdown
(2)
(1)
register
register
register
Bit5
0
0
Doc ID 13296 Rev 12
Width
(bits)
16
16
16
8
Bit4
FT1
0
Read-
(R/W)
Type
R/W
R/W
R/W
only
FT1 = fault tolerance1 bit
Bit 5 = must be set to '0'.
Bit 6 = must be set to '0'.
Bit 7 = must be set to '0'. Reserved.
Power-on
default
Bit3
FT0
4B00
5000
Table
N/A
0
00
Comparator mode
6). The entire register is volatile and
To store measured temperature data
Default = 75 °C
Set point for overtemperature
shutdown (T
POL
Bit2
0
Functional description
and
OS
Comments
) limit default = 80 °C
Interrupt mode on
Bit1
M
0
Bit0
LSB
SD
0
17/40

Related parts for STLM75M2E