LP8720TLX-B/NOPB National Semiconductor, LP8720TLX-B/NOPB Datasheet - Page 4

IC REG BUCK 5-LDO I2C 20USMD

LP8720TLX-B/NOPB

Manufacturer Part Number
LP8720TLX-B/NOPB
Description
IC REG BUCK 5-LDO I2C 20USMD
Manufacturer
National Semiconductor
Datasheet

Specifications of LP8720TLX-B/NOPB

Topology
Step-Down (Buck) Synchronous (1), Linear (LDO) (5)
Function
Any Function
Number Of Outputs
6
Frequency - Switching
2MHz
Voltage/current - Output 1
0.8 V ~ 2.3 V, 400mA
Voltage/current - Output 2
1.2 V ~ 3.3 V, 300mA
Voltage/current - Output 3
1.2 V ~ 3.3 V, 300mA
W/led Driver
No
W/supervisor
No
W/sequencer
Yes
Voltage - Supply
2.7 V ~ 4.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-UFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LP8720TLX-B/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
www.national.com
Device Description
OPERATION MODES
POWER-ON-RESET: After VBATT gets above POR higher threshold DEFSEL-pin and IDSEL-pin are read. Then all internal
STANDBY:
START UP:
IDLE:
SHUT DOWN:
Additional Functions
SLEEP:
DVS:
INTERRUPT: If interrupt is not masked then PMU forces IRQ_N low if temperature crossed TSD_EW limit (thermal shutdown
If sum of all LDO’s load currents and BUCK load current is no higher than 5mA then user can put PMU to SLEEP.
In SLEEP PMU GND current is minimized. In SLEEP LDO’s and BUCK cannot be loaded with big current.
There are 2 possibilities to use SLEEP:
1) Control via Serial Interface.
2) Control by DVS-pin.
Dynamic Voltage Scaling allows using 2 voltage sets for BUCK. There are 2 possibilities to use DVS:
1) Control via Serial Interface.
2) Control by DVS-pin.
early warning) or/and thermal shutdown event took place. IRQ_N is released by reading Interrupt register.
registers of LP8720 are reset to the default values and after that LP8720 goes to STANDBY mode. This
process duration max is 500 µs.
In STANDBY mode only serial interface is working and all other PMU functions are disabled – PMU is in
low power condition. In STANDBY mode LP8720 can be (re)configured via Serial Interface.
START UP sequence is defined by registers contents. START UP sequence starts:
1) If rising edge on EN-pin.
2) After cooling down from thermal shutdown event if EN=HI.
It is not recommended to write to LP8720 registers during START UP. If doing so then current START UP
sequence may become undefined.
PMU will enter into IDLE mode (normal operating mode) after end of START UP sequence. In IDLE mode
all LDO’s and BUCK can be enabled/disabled via Serial Interface. Also in IDLE mode LP8720 can be (re)
configured via Serial Interface.
SHUT DOWN sequence is “reverse order of start up sequence” and this is defined by registers contents.
SHUT DOWN starts
1) If falling edge on EN-pin.
2) If temperature exceeds thermal shutdown threshold TSD +160°C.
It is not recommended to write to LP8720 registers during SHUT DOWN. If doing so then current SHUT
DOWN sequence may become undefined.
4