E48SR12006NNFA Delta Electronics, E48SR12006NNFA Datasheet - Page 10

no-image

E48SR12006NNFA

Manufacturer Part Number
E48SR12006NNFA
Description
MODULE DC/DC 8TH BRICK 12V 6A
Manufacturer
Delta Electronics
Series
Delphi E48SRr
Type
Isolated with UVLOr
Datasheet

Specifications of E48SR12006NNFA

Operating Temperature
-40°C ~ 115°C
Power (watts) - Rated
72W
Efficiency
92.5%
Approvals
CE, cUL, TUV, UL
Output
12V
Number Of Outputs
1
Power (watts)
72W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
8-DIP Module, 1/8 Brick
1st Output
12 VDC @ 6A
Size / Dimension
2.30" L x 0.90" W x 0.33" H (58.4mm x 22.8mm x 8.4mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Other names
941-1050
E48SR12007_05142009
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
Figure 20: Wind tunnel test setup
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
MEASURED BELOW
following
TEMPERATURE
AIR VELOCITY
AND AMBIENT
THE MODULE
FACING PWB
encountered
figure
AIR FLOW
shows
in
PWB
50.8 (2.0”)
MODULE
12.7 (0.5”)
the
most
wind
electronics
tunnel
Thermal Derating
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power module
should always be operated below the maximum operating
temperature. If the temperature exceeds the maximum
module temperature, reliability of the unit may be affected.
THERMAL CURVES
Figure 21: Hot spot temperature measured point
Figure 22: Output current vs. ambient temperature and air
velocity@Vin=48V (Transverse Orientation)
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
The allowed maximum hot spot temperature is defined at 115
20
Output Current(A)
25
Convection
Natural
E48SR12007(Standard) Output Current vs. Ambient Temperature and Air Velocity
30
35
100LFM
40
@Vin = 48V (Transverse Orientation)
200LFM
45
300LFM
50
400LFM
55
500LFM
60
65
70
Ambient Temperature ( ℃ )
75
80
85
10