E48SR12006NNFA Delta Electronics, E48SR12006NNFA Datasheet - Page 7

no-image

E48SR12006NNFA

Manufacturer Part Number
E48SR12006NNFA
Description
MODULE DC/DC 8TH BRICK 12V 6A
Manufacturer
Delta Electronics
Series
Delphi E48SRr
Type
Isolated with UVLOr
Datasheet

Specifications of E48SR12006NNFA

Operating Temperature
-40°C ~ 115°C
Power (watts) - Rated
72W
Efficiency
92.5%
Approvals
CE, cUL, TUV, UL
Output
12V
Number Of Outputs
1
Power (watts)
72W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
8-DIP Module, 1/8 Brick
1st Output
12 VDC @ 6A
Size / Dimension
2.30" L x 0.90" W x 0.33" H (58.4mm x 22.8mm x 8.4mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Other names
941-1050
E48SR12007_05142009
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few μH, we advise adding a 10 to 100 μF electrolytic
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the
input of the module to improve the stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate
in a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB
layout issues, please contact Delta’s technical support
team. An external input filter module is available for
easier EMC compliance design. Application notes to
assist designers in addressing these issues are pending
to release.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and
IEC60950-1999, if the system in which the power module
is to be used must meet safety agency requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2 or
SELV. An additional evaluation is needed if the source
is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If
the input source is a hazardous voltage which is greater
than 60 Vdc and less than or equal to 75 Vdc, for the
module’s output to meet SELV requirements, all of the
following must be met:
When installed into a Class II equipment (without
grounding), spacing consideration should be given to the
end-use installation, as the spacing between the module
and mounting surface have not been evaluated.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
normal-blow fuse with 10A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or
un-encapsulated and/or open frame type power modules.
For assistance on appropriate soldering and cleaning
procedures, please contact Delta’s technical support
team.
mains by reinforced or double insulation.
accessible.
one Vo pin shall also be grounded.
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
The input source must be insulated from the ac
The input terminals of the module are not operator
If the metal baseplate is grounded, one Vi pin and
A SELV reliability test is conducted on the system
drying
are
especially
important
for
7

Related parts for E48SR12006NNFA