MMA7660FCT Freescale Semiconductor, MMA7660FCT Datasheet - Page 21

ACCELEROMETER 3X3 DGTL 10-DFN

MMA7660FCT

Manufacturer Part Number
MMA7660FCT
Description
ACCELEROMETER 3X3 DGTL 10-DFN
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MMA7660FCT

Axis
X, Y, Z
Acceleration Range
±1.5g
Sensitivity
21.33 count/g
Voltage - Supply
2.4 V ~ 3.6 V
Output Type
Digital
Interface
I²C
Mounting Type
Surface Mount
Package / Case
10-DFN
Sensing Axis
Triple
Acceleration
1.5 g
Digital Output - Number Of Bits
6 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.4 V
Supply Current
294 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Shutdown
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Bandwidth
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMA7660FCT
Manufacturer:
FSC
Quantity:
3 000
Part Number:
MMA7660FCT
Manufacturer:
FREESCALE
Quantity:
20 000
$09: Tap/Pulse Detection Register (Read/Write)
PDET
NOTE: If XDA = YDA = ZDA = 0, samples per second is 120 samples/second, and Auto-Wake/Sleep feature is enabled,
XDA
1: X-axis is disabled for tap detection
0: X-axis is enabled for tap detection
YDA
1: Y-axis is disabled for tap detection
0: Y-axis is enabled for tap detection
$0A: PD: Tap/Pulse Debounce Count Register (Read/Write)
Sensors
Freescale Semiconductor
PDTH[4:0]
00000000
00000001
00000010
00000011
11111101
11111110
11111111
PD[4:0]
PD[7]
ZDA
00000
00001
00010
00011
11101
11110
11111
D7
D7
0
0
...
...
the tap interrupt will reset the sleep counter.
The tap detection debounce filtering requires 2 adjacent tap detection tests to be the same to trigger a tap event and set the
Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection
response time is nominally 0.52 ms.
Tap detection debounce filtering requires 3 adjacent tap detection tests to be the same to trigger a tap event and set the Tap
bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection
response time is nominally 0.78 ms.
Tap detection debounce filtering requires 4 adjacent tap detection tests to be the same to trigger a tap event and set the Tap
bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection
response time is nominally 1.04 ms.
... and so on up to...
Tap detection debounce filtering requires 254 adjacent tap detection tests to be the same to trigger a tap event and set the
Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection
response time is nominally 66.04 ms.
Tap detection debounce filtering requires 255 adjacent tap detection tests to be the same to trigger a tap event and set the
Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection
response time is nominally 66.3 ms.
Tap detection debounce filtering requires 256 adjacent tap detection tests to be the same to trigger a tap event and set the
Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection
response time is nominally 66.56 ms.
Tap detection threshold is ±1 count
Tap detection threshold is ±2 counts
Tap detection threshold is ±3 counts
... and so on up to...
Tap detection threshold is ±29 counts
Tap detection threshold is ±30 counts
Tap detection threshold is ±31 counts
YDA
PD[6]
D6
D6
0
0
XDA
PD[5]
D5
0
D5
0
PDTH[4]
PD[4]
D4
D4
0
0
DESCRIPTION
DESCRIPTION
ZDA
1: Z-axis is disabled for tap detection
0: Z-axis is enabled for tap detection
PDTH[3]
PD[3]
D3
D3
0
0
PDTH[2]
PD[2]
D2
D2
0
0
PDTH[1]
PD[1]
D1
D1
0
0
MMA7660FC
PDTH[0]
PD[0]
D0
D0
0
0
21