SCA3000-E05 VTI Technologies, SCA3000-E05 Datasheet - Page 10

ACCELEROMETER 3-AXIS +/-18G SPI

SCA3000-E05

Manufacturer Part Number
SCA3000-E05
Description
ACCELEROMETER 3-AXIS +/-18G SPI
Manufacturer
VTI Technologies
Series
SCA3000r
Datasheets

Specifications of SCA3000-E05

Axis
X, Y, Z
Acceleration Range
±18g
Sensitivity
160 counts/g
Voltage - Supply
2.35 V ~ 3.6 V
Output Type
Digital
Interface
SPI
Mounting Type
Surface Mount
Package / Case
18-SMD
For Use With
551-1050 - BOARD PWB W/SCA3000-E05551-1041 - SCA3000-D01 DEMOKIT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Bandwidth
-
Other names
551-1048-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCA3000-E05 PWB
Manufacturer:
VTI Technologies
Quantity:
135
2.3.2
2.3.3
VTI Technologies Oy
www.vti.fi
Usage
Examples
The absolute value of programmable Threshold Level (TL) is 0 < |TL| < FS g (FS is sensor full
scale measuring range). NOTE: Due to power consumption optimization, the step size between
each step and axis is not the same, see section 3.4 for threshold level details.
The triggering condition can be defined using OR/AND logic:
1. Any sensing direction can be configured to trigger the interrupt (OR condition).
2. Any sensing direction can be configured to be required to trigger the interrupt (AND condition).
Figure 3. Motion detector operation.
The MD mode can be enabled by setting the MODE bits in the MODE register to "011". The trigger
condition can be defined by setting REQ_Z, REQ_Y, REQ_X, EN_Z, EN_Y and EN_X bits in
MD_CTRL register and Z_TH, Y_TH and Z_TH bits in MD_Z_TH, MD_Y_TH and MD_X_TH
registers, respectively. See section 3.4 for the configuration register and section 2.7 for the
interrupt functionality details.
In MD mode, acceleration data is not available in registers X_LSB, X_MSB, Y_LSB, Y_MSB,
Z_LSB, Z_MSB and BUF_DATA.
A simple example of motion detection usage:
In the next example, the motion detector is configured to give an interrupt on motion only in the X-
OR Y-axis direction:
Acceleration
X, Y or Z
INT output
1. Write "00000011" (03h) into the MODE register (enable motion detection mode,
2. Acceleration data is not available when the SCA3000 is in motion detection mode.
3. The INT-pin is activated when motion is detected, see section 2.7 for detailed INT-pin
1. Write "00000011" (03h) into MODE register (enable motion detection mode,
2. Write "00000000" (00h) into UNLOCK register
3. Write "01010000" (50h) into UNLOCK register
4. Write "10100000" (A0h) into UNLOCK register
5. Write "00000010" (02h) into CTRL_SEL register (to select indirect MD_CTRL register)
6. Write "00000011" (03h) into CTRL_DATA register (this data is written into MD_CTRL
+TL
-TL
"1"
"0"
MODE_BITS = '011').
information.
MODE_BITS = '011')
register, enable trigger on Y-channel, EN_Y = '1', enable trigger on X-channel, EN_X = '1')
Acceleration exceeds
the threshold level
due to motion
T1
T1
Doc.Nr. 8257300A.07
T2
T2
T3
T3
T4
T4
T5
T5
T6
T6
T7
T7
Unlock sequence for register lock
T8
T8
Time