SCA3000-E05 VTI Technologies, SCA3000-E05 Datasheet - Page 21

ACCELEROMETER 3-AXIS +/-18G SPI

SCA3000-E05

Manufacturer Part Number
SCA3000-E05
Description
ACCELEROMETER 3-AXIS +/-18G SPI
Manufacturer
VTI Technologies
Series
SCA3000r
Datasheets

Specifications of SCA3000-E05

Axis
X, Y, Z
Acceleration Range
±18g
Sensitivity
160 counts/g
Voltage - Supply
2.35 V ~ 3.6 V
Output Type
Digital
Interface
SPI
Mounting Type
Surface Mount
Package / Case
18-SMD
For Use With
551-1050 - BOARD PWB W/SCA3000-E05551-1041 - SCA3000-D01 DEMOKIT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Bandwidth
-
Other names
551-1048-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCA3000-E05 PWB
Manufacturer:
VTI Technologies
Quantity:
135
VTI Technologies Oy
www.vti.fi
Address value: 00010
Register name: MD_CTRL, Motion Detector control (Indirect access via CTRL_SEL)
Address value: 00011
Register name: MD_Y_TH, Motion Detector Y-threshold (Indirect access via CTRL_SEL)
Address value: 00100
Register name: MD_X_TH, Motion Detector X-threshold (Indirect access via CTRL_SEL)
Address value: 00101
Register name: MD_Z_TH, Motion Detector Z-threshold (Indirect access via CTRL_SEL)
Initial values for registers MD_X_TH, MD_Y_TH and MD_Z_TH vary with SCA3000 product types.
Initial value is:
The bit level descriptions for registers MD_X_TH, MD_Y_TH and MD_Z_TH are presented in,
Table 11 ...Table 14 below. The threshold levels are in unsigned format and they are absolute
values for the acceleration that triggers the motion detector interrupt. Values presented below are
typical threshold values and they are not factory calibrated.
Bits
Bits
Bits
Bits
7:6
7:0
7:0
7:0
5
4
3
2
1
0
10h for SCA3000-D01, SCA3000-D02, SCA3000-E01 and SCA3000-E02
08h for SCA3000-E04 and SCA3000-E05
10h or 08h
10h or 08h
10h or 08h
Value
Initial
0
0
0
1
1
1
Value
Value
Value
Initial
Initial
Initial
REQ_Z
REQ_X
REQ_Y
Name
EN_Y
EN_Z
EN_X
Doc.Nr. 8257300A.07
Name
Name
Name
Y_TH
X_TH
Z_TH
Description
Reserved
1 – Require trigger on Z-channel
0 – Not required
1 – Require trigger on X-channel
0 – Not required
1 – Require trigger on Y-channel
0 – Not required
1 – Enable trigger on Z-channel
0 – Not required
1 – Enable trigger on X-channel
0 – Not required
1 – Enable trigger on Y-channel
0 – Not required
Description
Threshold for Y-acceleration change when MD
is used.
Description
Threshold for X-acceleration change when MD
is used.
Description
Threshold for Z-acceleration change when MD is
used.
Note
Bits 5:3 can be
used to build logical
AND operation
between channels.
Example:
X and Y = Require
X and Y, ignore Z
→ 00 011 011
Bits 2:0 can be
used to build logical
OR operation
between channels.
Example:
X or Y = Disable Z
→ 00 000 011
SCA3000 Series
Rev.A.07
21/ 43

Related parts for SCA3000-E05