E6C2-CWZ6C 200P/R 2M Omron, E6C2-CWZ6C 200P/R 2M Datasheet - Page 9

no-image

E6C2-CWZ6C 200P/R 2M

Manufacturer Part Number
E6C2-CWZ6C 200P/R 2M
Description
ENCODER ROTARY 5-24V 200RESOL 2M
Manufacturer
Omron
Series
E6C2r

Specifications of E6C2-CWZ6C 200P/R 2M

Encoder Type
Optical
Output Type
Quadrature with Index (Incremental)
Pulses Per Revolution
200
Voltage - Supply
5 ~ 24VDC
Actuator Type
6mm Dia Flatted End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Vertical
Termination Style
Cable Leads
Product
Mechanical
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E6C2-CWZ6C200P/R2M
E6C2CWZ6C200PR2M
E6C2-C
J C200H-CTjj HIGH-SPEED COUNTER UNIT
J CQM1-CPU43-EV1 (AS BUILT-IN HIGH-SPEED COUNTER)
The pulse output of the E6C2-C can be directly input into IN04,
IN05, and IN06 of the CPU Unit to use these three points as a
built-in high-speed counter.
The single-phase response speed is 5 kHz, and the two-phase
response speed is 2.5 kHz. The count value is within a range
between 0 and 65,535 in increment mode and - -32,767 and
32,767 in decrement mode.
The operating mode of the high-speed counter is set with the PC
Setup in the DM area.
Count Mode
Applicable model: E6C2-CWZ6C
Typical model: C200H-CT001-V1
Note: Apply the following connections if the power supply to
Up/Down mode
Incrementing
mode
Normal mode
Encoder at 0 V
12-VDC power supply
the E6C2-C is 5 or 24 V.
Phase A and power supply: 5 V to A19 and 24 V to
B20
Phase B and power supply: 5 V to A17 and 24 V to
B18
Phase B
+12 V
0 V
Phase A
Increment/decrement counter uses phases
A and B.
Increment counter uses phase A only.
IN04 through IN06 are used for normal
input.
+12 V
0 V
Phase A
Phase B
Applicable Model: E6C2-CWZ6C
Reset
The present count value can be reset with the soft-reset function or
the AND of soft reset and phase Z input.
Output
Applicable Model: E6C2-CWZ5B
Note: Apply the following connections if the power supply to
10
Target value
Range
comparison
E6C2-CWZ6C
the E6C2-C is 12 or 24 V.
Phase A and power supply: 12 V to A8/B8 and 24 V
A9/B9
Phase B and power supply: 12 V to A12/B12 and 24 to
A13/B13
Phase Z and power supply: 12 V to A16/B16 and 24 V
to A17/B17
12-VDC power supply
Phase A
Phase B
Phase Z
When the count value reaches the target
value, the specified subroutine is executed.
A maximum of 16 target values can be set.
When the count value is within the range,
the specified subroutine is executed. A
maximum of 8 ranges can be set with upper
and lower limits.
+12 V
0 V
+12 V
Phase B
Phase A
Phase Z
0 V
Phase Z
Phase B
Phase A
CQM1
0 V
CQM1-CPU43
Phase A
Phase Z
Phase B
5 to
24 VDC
IR 0000
E6C2-C

Related parts for E6C2-CWZ6C 200P/R 2M