011796 AP (SAK4/6) Weidmuller, 011796 AP (SAK4/6) Datasheet - Page 75

END COVER, BUFF

011796 AP (SAK4/6)

Manufacturer Part Number
011796 AP (SAK4/6)
Description
END COVER, BUFF
Manufacturer
Weidmuller
Series
Wr
Datasheet

Specifications of 011796 AP (SAK4/6)

Svhc
No SVHC (15-Dec-2010)
Colour
Buff
External Length / Height
51.5mm
Accessory Type
End / Intermediate Plate
For Use With
W Series
Lead Free Status / RoHS Status
na
Easy to modify
Once joined together the distribution strip
simply clips onto the base element. There
are no tools necessary. Should you want
to remove a distribution strip you can sim-
ply pry it off with a cheese-head screw dri-
ver.
Connection of initiators
No further terminal variations are required
for power supply since this ensues simply
by adding additional base elements that
have built-in cross-connection.
An example:
If you wanted to connect 9 initiators, you
would simply need 10 3-way or 4-way
base elements, 10 brown ZVL 1.5 BR dis-
tributor elements and 10 blue ZVL 1.5 BL
(-) distributor elements. The extra element
is the feed. The number of distributor ele-
ments is therefore n + 1, where n is the
number of initiator / actuators being con-
nected.
Connection of actuators
Ground (PE) can be connected with a PE
element or using a standard PE terminal
(such as the ZPE 22.5). The PE base ele-
ment has the proven PE foot from the ZPE
2.5 and contacts automatically with the
ZVL 1.5 PE distributor strip when mount-
ed.
The contact takes place between the
female contact of the first distributor ele-
ment and the male contact in the PE foot
of the PE base element.
This is the innermost ratchet of both the
3-way and 4-way variants. If you use a
standard PE terminal, this will have to be
connected to the ZVL 1.5 PE distributor
element with a suitable wire. The n+1 rule
for the number of distributor elements also
applies here. In other words, just 1 PE ele-
ment per series (n) of base elements.
Because of the design, the PE element
should always be to the left of the block.
Pluggable cross-connection system
If you do need to cross-connect a signal
line you can use the familiar ZQV/2.5 from
Z-Series.
Not much space required
The TOP-connection also ensures easy
access and easy- to-locate wiring. Wiring
up the connector is easier and more
reliable since wiring errors are quickly
recognised. The strain on the wiring is
lower with a TOP-connection. The combi-
nation with tension clamp technology
improves user-friendliness.
A welcome feature of this type
of connector is the ability to use extremely
narrow ducting and narrow flat enclosures.
Distance to body of terminal:
a = 6 mm
b = 11.5 mm for 40 mm height
= 20.2 mm for 60 mm height
a
b
h
2/63