FT4232HL-R FTDI, FT4232HL-R Datasheet - Page 19

USB-UART/MPSSE, 4232, QUAD, 64LQFP

FT4232HL-R

Manufacturer Part Number
FT4232HL-R
Description
USB-UART/MPSSE, 4232, QUAD, 64LQFP
Manufacturer
FTDI
Datasheet

Specifications of FT4232HL-R

No. Of Channels
4
Data Rate
480Mbps
Supply Voltage Range
1.62V To 1.98V, 2.97V To 3.63V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
64
Svhc
No SVHC
Bridge Type
USB -
Rohs Compliant
Yes
Case Style
LQFP
Max Supply Voltage
3.63V
Min Supply Voltage
2.97V
Termination Type
SMD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FT4232HL-REEL
Manufacturer:
FTDI
Quantity:
4 713
Part Number:
FT4232HL-REEL
Manufacturer:
FTDI, Future Technology Devices International Ltd
Quantity:
10 000
Part Number:
FT4232HL-REEL
Manufacturer:
FTDI
Quantity:
20 000
Part Number:
FT4232HL-REEL
0
Company:
Part Number:
FT4232HL-REEL
Quantity:
20 000
Document No.: FT_000060
FT4232H QUAD HIGH SPEED USB TO MULTIPURPOSE UART/MPSSE IC
Datasheet Version 2.10
Clearance No.: FTDI#78
4.3.3 RS485 Configuration
Figure 4.3 illustrates how the FT4232H can be configured as a dual RS485 interface. The FT4232H can
have all 4 channels connected as RS485, but only channel A and channel C are shown for clarity.
Figure 4.3 Dual RS485 Configuration
In this case both channel A and channel C are configured as RS485 operating at TTL levels and a level
converter device (half duplex RS485 transceiver) is used to convert the TTL level signals from the
FT232H to RS485 levels. It has separate enables on both the transmitter and receiver. With RS485, the
transmitter is only enabled when a character is being transmitted from the UART. The TXDEN pins on the
FT4232H are provided for exactly that purpose, and so the transmitter enables are wired to the TXDEN‟ s.
The receiver enable is active low, so it is wired to the PWREN# pin to disable the receiver when in USB
suspend mode.
RS485 is a multi-drop network – i.e. many devices can communicate with each other over a single two
wire cable connection. The RS485 cable requires to be terminated at each end of the cable. Links are
provided to allow the cable to be terminated if the device is physically positioned at either end of the
cable.
In this example the data transmitted by the FT4232H is also received by the device that is transmitting.
This is a common feature of RS485 and requires the application software to remove the transmitted data
from the received data stream. With the FT4232H it is possible to do this entirely in hardware – simply
modify the schematic so that RXD of the FT4232H is the logical OR of the level converter device receiver
output with TXDEN using an HC32 or similar logic gate
Copyright © 2010 Future Technology Devices International Limited
19