Specifications of SC16C654BIA68

No. Of Channels
4
Data Rate
5Mbps
Supply Voltage Range
2.25V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
PLCC
No. Of Pins
68
Svhc
No SVHC (18-Jun-2010)
Uart Features
Programmable Xon/Xoff Characters, Software Selectable Baud Rate Generator
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C654BIA68
Manufacturer:
NXP
Quantity:
152
Part Number:
SC16C654BIA68,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C654BIA68,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C654BIA68,529
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
9397 750 14965
Product data sheet
7.10 Enhanced Feature Register (EFR)
7.9 Scratchpad Register (SPR)
The SC16C654B/654DB provides a temporary data register to store 8 bits of user
information.
Enhanced features are enabled or disabled using this register.
Bits 0 through 4 provide single or dual character software flow control selection. When the
Xon1 and Xon2 and/or Xoff1 and Xoff2 modes are selected, the double 8-bit words are
concatenated into two sequential numbers.
Table 22:
Bit
7
6
5
4
3:0
Symbol
EFR[7]
EFR[6]
EFR[5]
EFR[4]
EFR[3:0]
Enhanced Feature Register bits description
5 V, 3.3 V and 2.5 V quad UART, 5 Mbit/s (max.) with 64-byte FIFOs
Description
Auto CTS. Automatic CTS Flow Control.
Auto RTS. Automatic RTS may be used for hardware flow control by enabling
EFR[6]. When Auto RTS is selected, an interrupt will be generated when the
receive FIFO is filled to the programmed trigger level and RTS will go to a
logic 1 at the next trigger level. RTS will return to a logic 0 when data is
unloaded below the next lower trigger level. The state of this register bit
changes with the status of the hardware flow control. RTS functions normally
when hardware flow control is disabled.
Special Character Detect.
Enhanced function control bit. The content of IER[7:4], ISR[5:4], FCR[5:4],
and MCR[7:5] can be modified and latched. After modifying any bits in the
enhanced registers, EFR[4] can be set to a logic 0 to latch the new values.
This feature prevents existing software from altering or overwriting the
SC16C654B/654DB enhanced functions.
Cont-3:0 Tx, Rx control. Logic 0 or cleared is the default condition.
Combinations of software flow control can be selected by programming these
bits. See
logic 0 = automatic CTS flow control is disabled (normal default condition)
logic 1 = enable Automatic CTS flow control. Transmission will stop when
CTS goes to a logical 1. Transmission will resume when the CTS pin
returns to a logical 0.
logic 0 = automatic RTS flow control is disabled (normal default condition)
logic 1 = enable Automatic RTS flow control
logic 0 = special character detect disabled (normal default condition)
logic 1 = special character detect enabled. The SC16C654B/654DB
compares each incoming receive character with Xoff2 data. If a match
exists, the received data will be transferred to FIFO and ISR[4] will be set to
indicate detection of special character. Bit-0 in the X-registers corresponds
with the LSB bit for the receive character. When this feature is enabled, the
normal software flow control must be disabled (EFR[3:0] must be set to a
logic 0).
logic 0 = disable (normal default condition)
logic 1 = enable
Rev. 02 — 20 June 2005
Table
23.
SC16C654B/654DB
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
35 of 58