83203 SENSONOR TECHNOLOGIES AS, 83203 Datasheet - Page 12

no-image

83203

Manufacturer Part Number
83203
Description
IC, SENSOR, GYRO, SAR10, 16SOIC
Manufacturer
SENSONOR TECHNOLOGIES AS
Datasheet

Specifications of 83203

Sensor Case Style
SOIC
No. Of Pins
16
Supply Voltage Range
4.45V To 5.5V
Operating Temperature Range
-40°C To +90°C
Ic Generic Number
SAR10H
Interface
SPI
Sensitivity
0.03°/
Interface Type
SPI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
8
Internally in the SAR10(H), 6 error monitoring functions are employed to make sure an irregular output angular rate is
detected. If any of the monitoring functions detects an irregular condition the corresponding flag becomes a ‘0’,
otherwise a ‘1’. The Status Register flags are available to the application via the RSR SPI command. It is assumed
that a flag can signal an “error” for any length of time. To make sure short error (‘0’) pulses are visible to the
application, the ‘0’ pulses are "stretched" in time to between 1.5 and 2.0 ms.
After power-up and until the device start-up is complete the output from the RARH and RARLX commands is
substituted by the Error Code, see 5.3. After start-up, if any of the flags go to ‘0’ (the internal monitoring functions
indicate that the output is irregular), the Error Code is the output from the RARH and RARLX commands, and also
internal digital signal processing is held. This signaling continues indefinitely until the device is powered down, or, in
case of some of the conditions (see ‘Recoverable’ in the table above), until the PRCEN command is issued.
The PRCEN command execution must obey the following algorithm:
Note that for the PRCEN command to take effect, the Safe Guard must first be disabled by means of the SGDIS1,-2
and -3 commands. To resume normal operation after recovery, the SafeGuard must be re-enabled by using the SGEN
command. If, before the Safe Guard was disabled, a non-recoverable error condition existed, the SAR10(H) will return
to responding with the Error Code to RARH, -LX commands as well as holding internal digital signal processing even
after the SGEN command was issued (the error is non-recoverable). Also note that while the SafeGuard is disabled,
no error condition will be latched.
TS1162 rev. 1
Bit
Position
7
6
5
4
3
2
1
0
Status Register and Internal Diagnostic Monitoring
1. Wait until no recoverable error conditions are flagged (polling the Status Register).
2. Wait minimum 30 ms (recommended 100 ms).
3. Execute the SGDIS1, -2 and -3 commands.
4. Execute the PRCEN command.
5. Execute the SGEN command
Flag Name
ADC_OK
SIG_OK
OTPPAR_OK
ATEST_
INACTIVE
PRNG_OK
DET_OK
EXC_OK
(no name)
DATASHEET
Monitoring function
ADC_OK is ‘0’ if an ADC overflow occurs, otherwise ‘1’.
SIG_OK is ‘0’ if an arithmetic overflow or underflow occurs in the
digital signal processing, EXCEPT if the signal amplitude exceeds
the output range in the final scaling (by the S0INV parameter),
otherwise ‘1’.
OTPPAR_OK is ‘0’ if OTP parity check fails, otherwise‘1’.
ATEST_INACTIVE is ‘0’ if an analog test mode is active,
otherwise ‘1’. This monitoring function will not result in any Error
Code signaling.
PRNG_OK is ‘0’ if the AVDD voltage is out of range, otherwise ‘1’.
DET_OK is ‘0’ if a sensor die detection electrode connection is
open or if a leakage current is present on one or both electrodes,
otherwise ‘1’.
EXC_OK is ‘0’ if the excitation control loop fails to lock on
resonance frequency such that the excitation amplitude falls
below a critical level, otherwise ‘1’.
Not used. Always ‘1’.
- 12 -
SAR10 GYRO SENSOR SERIES
SAR10, SAR10H
Recoverable
Yes
No
No
-
No
No
Yes
-