PIC16F506T-I/SL Microchip Technology, PIC16F506T-I/SL Datasheet - Page 7

no-image

PIC16F506T-I/SL

Manufacturer Part Number
PIC16F506T-I/SL
Description
IC,MICROCONTROLLER,8-BIT,PIC CPU,CMOS,SOP,14PIN,PLASTIC
Manufacturer
Microchip Technology
Series
PIC® 16Fr

Specifications of PIC16F506T-I/SL

Rohs Compliant
YES
Core Processor
PIC
Core Size
8-Bit
Speed
20MHz
Peripherals
POR, WDT
Number Of I /o
11
Program Memory Size
1.5KB (1K x 12)
Program Memory Type
FLASH
Ram Size
67 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 4x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Processor Series
PIC16F
Core
PIC
Data Bus Width
8 bit
Data Ram Size
67 B
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
12
Number Of Timers
1
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000
Minimum Operating Temperature
- 40 C
On-chip Adc
8 bit, 3 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Connectivity
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC16F506T-I/SL
Manufacturer:
ROHM
Quantity:
400 000
Part Number:
PIC16F506T-I/SL
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
3.1.2.5
The End Programming command terminates the
program process. A delay of T
required before the next command to allow the internal
programming voltage to discharge (see Figure 3-6).
FIGURE 3-6:
3.1.2.6
After this command is performed, the entire program
memory and Configuration Word is erased.
To perform a Bulk Erase of the program memory and
configuration fuses, the following sequence must be
performed (see Figure 3-12).
1.
2.
3.
4.
5.
6.
 2010 Microchip Technology Inc.
Note:
Note:
Read and save 0x3FF oscillator Calibration bits
and 0x404 backup OSCCAL bits into computer/
programmer temporary memory.
Enter Program/Verify mode. PC is set to
Configuration Word address.
Perform a Bulk Erase Program Memory
command.
Wait T
Restore OSCCAL bits.
Restore backup OCCAL bits.
ICSPCLK
ICSPDAT
ERA
A fully erased part will read ‘1’s in every
program memory location.
The oscillator Calibration bits are erased if
a Bulk Erase is invoked. They must be
read and saved prior to erasing the device
and restored during the programming
operation. Oscillator Calibration bits are
stored at the Reset vector as the operand
of a MOVLW instruction.
End Programming
Bulk Erase Program Memory
to complete Bulk Erase.
END PROGRAMMING (EXTERNALLY TIMED)
DIS
1
0
(see Table 6-1) is
2
1
T
3
1
SET
1
4
1
To perform a full device Bulk Erase of the program
memory, configuration fuses, user IDs and backup
OSCCAL, the following sequence must be performed
(see Figure 3-13).
1.
2.
3.
4.
5.
6.
7.
T
HLD
Read and save 0x3FF oscillator Calibration bits
and 0x404 backup OSCCAL bits into computer/
programmer temporary memory.
Enter Program/Verify mode.
Increment PC to 0x400 (first user ID location).
Perform a Bulk Erase command.
Wait T
Restore OSCCAL bits.
Restore backup OSCCAL bits.
5
x
1
ERA
6
x
to complete Bulk Erase.
T
DIS
1
Next Command
PIC16F506
2
DS41258C-page 7

Related parts for PIC16F506T-I/SL