PIC18LF4221-I/ML Microchip Technology, PIC18LF4221-I/ML Datasheet - Page 146

4 KB Flash, 512 RAM 44 QFN 8x8x0.9mm TUBE

PIC18LF4221-I/ML

Manufacturer Part Number
PIC18LF4221-I/ML
Description
4 KB Flash, 512 RAM 44 QFN 8x8x0.9mm TUBE
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18LF4221-I/ML

Core Processor
PIC
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, HLVD, POR, PWM, WDT
Number Of I /o
36
Program Memory Size
4KB (2K x 16)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 13x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
44-QFN
Processor Series
PIC18LF
Core
PIC
Data Bus Width
8 bit
Data Ram Size
512 B
Interface Type
EUSART, I2C, MSSP, SPI
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
36
Number Of Timers
4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000, ICE4000, DV164136
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 13 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
PIC18F2221/2321/4221/4321 FAMILY
16.1
Each Capture/Compare/PWM module is associated
with a control register (generically, CCPxCON) and a
data register (CCPRx). The data register, in turn, is
comprised of two 8-bit registers: CCPRxL (low byte)
and CCPRxH (high byte). All registers are both
readable and writable.
16.1.1
The CCP modules utilize Timers 1, 2 or 3, depending
on the mode selected. Timer1 and Timer3 are available
to modules in Capture or Compare modes, while
Timer2 is available for modules in PWM mode.
TABLE 16-1:
TABLE 16-2:
DS39689F-page 146
CCP1 Mode CCP2 Mode
Note 1:
Compare
Compare
Compare
Capture
Capture
Capture
PWM
PWM
PWM
CCP/ECCP Mode
Compare
Capture
(1)
(1)
(1)
CCP Module Configuration
PWM
Includes standard and Enhanced PWM operation.
CCP MODULES AND TIMER
RESOURCES
Compare
Compare
Compare
Capture
Capture
Capture
PWM
PWM
CCP MODE – TIMER
RESOURCES
INTERACTIONS BETWEEN CCP1 AND CCP2 FOR TIMER RESOURCES
PWM
(1)
(1)
Each module can use TMR1 or TMR3 as the time base. The time base can be different
for each CCP.
CCP2 can be configured for the Special Event Trigger to reset TMR1 or TMR3
(depending upon which time base is used). Automatic A/D conversions on trigger event
can also be done. Operation of CCP1 could be affected if it is using the same timer as a
time base.
CCP1 can be configured for the Special Event Trigger to reset TMR1 or TMR3
(depending upon which time base is used). Operation of CCP2 could be affected if it is
using the same timer as a time base.
Either module can be configured for the Special Event Trigger to reset the time base.
Automatic A/D conversions on CCP2 trigger event can be done. Conflicts may occur if
both modules are using the same time base.
None
None
None
None
Both PWMs will have the same frequency and update rate (TMR2 interrupt).
Timer1 or Timer3
Timer1 or Timer3
Timer Resource
Timer2
The assignment of a particular timer to a module is
determined by the Timer to CCP enable bits in the
T3CON register (Register 15-1). Both modules may be
active at any given time and may share the same timer
resource if they are configured to operate in the same
mode (Capture/Compare or PWM) at the same time. The
interactions between the two modules are summarized in
Figure 16-1 and Figure 16-2. In Timer1 in Asynchronous
Counter mode, the capture operation will not work.
16.1.2
The pin assignment for CCP2 (Capture input, Compare
and PWM output) can change, based on device config-
uration. The CCP2MX Configuration bit determines
which pin CCP2 is multiplexed to. By default, it is
assigned to RC1 (CCP2MX = 1). If the Configuration bit
is cleared, CCP2 is multiplexed with RB3.
Changing the pin assignment of CCP2 does not
automatically change any requirements for configuring
the port pin. Users must always verify that the appropri-
ate TRIS register is configured correctly for CCP2
operation, regardless of where it is located.
Interaction
CCP2 PIN ASSIGNMENT
© 2009 Microchip Technology Inc.