LC1D18BL TELEMECANIQUE, LC1D18BL Datasheet - Page 10

Contactor

LC1D18BL

Manufacturer Part Number
LC1D18BL
Description
Contactor
Manufacturer
TELEMECANIQUE
Type
General Purposer
Datasheets

Specifications of LC1D18BL

Contact Configuration
DPCO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Coil Power Vdc
5.4W
Length/height, External
77mm
Nom Operating Power
2.4W
External Width
45mm
Body Material
Silver Nickel
Current, Rating
18 A
Current, Rating Max
18
Function
Contactor
Horse Power Rating
15
Primary Type
Contactor
Relay Type
Electro Mechanical
Standards
IEC Approved
Operating Voltage
600VAC
Switching Power Ac1
3hp
Switching Power Ac3
15hp
Switching Current Ac1
32A
Switching Current Ac3
18A
Load Current Inductive
18A
Load Current Resistive
32A
No. Of Poles
3
Conforming to standards
Product certifications
Protective treatment
Degree of protection
Ambient air temperature
around the device
Recommendation
Rated insulation voltage
Rated operational voltage
Protection
Built-in protection
Indication
Electrical durability
Module type
Type of protection
Rated control circuit voltage (Uc)
Maximum peak voltage
Natural RC frequency
Mechanical latch block type
For mounting on contactor
Certification
Rated insulation voltage
Rated control circuit voltage
Power required
Maximum operating rate
On-load factor
Mechanical durability at Uc
Environment
“Auto - Man - Stop” control modules
Coil suppressor modules
Mechanical latch blocks
Characteristics
References:
pages 2/18 to 2/21
Schneider Electric
Dimensions:
pages 2/44 and 2/45
Unlatching can be manually operated locally or electrically controlled for remote operation.
The LA6-DK or LAD-6K latch coil and the LC1-D operating coil must not be energised simultaneously. The duration of
the LA6-DK or LAD-6K and LC1-D control signals must be
Conforming to IEC 68
Conforming to VDE 0106
Storage
Operation
Permissible for operation at Uc
The Auto - Man selector switch must only be operated with the Start - Stop (“O” “I”) switch in position “O”
Conforming to EN 60947-5-1
Conforming to EN 60947-5-1
Against electric shocks
Contactor coil suppression
By integral LED
In operating cycles
Conforming to IEC 947-5-1
" 50/60 Hz and $
For unlatching
In operating cycles/hour
In millions of operating cycles
TeSys contactors
Control modules, coil suppressor modules
and mechanical latch blocks
for model d contactors
Schemes:
pages 2/48 and 2/49
24/48 V
50/127 V
110/240 V
380/415 V
"
$
°C
°C
°C
V
V
kV
V
V
V
VA
W
Hz
Hz
Hz
Hz
IEC 947-5-1
UL, CSA
“TH”
Protection against direct finger contact IP 2X
- 40…+ 80
- 25…+ 55
- 25…+ 70
250
250
2
By varistor
Illuminates when the contactor coil is energised
20,000
LA4-DA
LAD-4RC
RC circuit
"
24…415
3 Uc
400
200
100
150
LA6-DK10
LC1D40…D65,
LP1-D65
UL, CSA
690
24…415
25
30
1200
10 %
0.5
100 ms.
LA4-DB
LAD-4T
Bidirectional
peak limiting
diode
" or $
24…72
2 Uc
LAD-6K10
LC1-D09…D38,
DT20…DT60
LA4-DC
Diode
$
12…250
Uc
LA6-DK20
LC1-D80…D150
LP1-D80
and LC1-D115
UL, CSA
690
24…415
25
30
1200
10 %
0.5
LA4-DE
LAD-4V
Varistor
" or $
24…250
2 Uc
2/41
2

Related parts for LC1D18BL