LC1D18BL TELEMECANIQUE, LC1D18BL Datasheet - Page 7

Contactor

LC1D18BL

Manufacturer Part Number
LC1D18BL
Description
Contactor
Manufacturer
TELEMECANIQUE
Type
General Purposer
Datasheets

Specifications of LC1D18BL

Contact Configuration
DPCO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Coil Power Vdc
5.4W
Length/height, External
77mm
Nom Operating Power
2.4W
External Width
45mm
Body Material
Silver Nickel
Current, Rating
18 A
Current, Rating Max
18
Function
Contactor
Horse Power Rating
15
Primary Type
Contactor
Relay Type
Electro Mechanical
Standards
IEC Approved
Operating Voltage
600VAC
Switching Power Ac1
3hp
Switching Power Ac3
15hp
Switching Current Ac1
32A
Switching Current Ac3
18A
Load Current Inductive
18A
Load Current Resistive
32A
No. Of Poles
3
Characteristics
Contact block type
Conforming to standards
Product certifications
Protective treatment
Degree of protection
Ambient air temperature
around the device
Maximum operating altitude
Cabling
Connection by spring terminals
Number of contacts
Rated operational voltage (Ue)
Rated insulation voltage (Ui)
Conventional thermal current (Ith)
Frequency of operational current
Minimum switching capacity
Short-circuit protection
Rated making capacity
Short-time rating
Insulation resistance
Non-overlap time
Overlap time
Time delay
(LAD-T, R and S contact blocks)
Accuracy only valid for setting range
indicated on the front face
Mechanical durability
Operational power of contacts
References:
pages 2/17 and 2/18
Environment
Instantaneous and time delay contact characteristics
2/38
Dimensions:
pages 2/44 and 2/45
Conforming to IEC 68
Conforming to VDE 0106
Storage
Operation
Permissible for operation at Uc
Without derating
Phillips N° 2 and Ø 6 mm
Flexible or solid cable with or without cable end
Flexible or solid cable without cable end
Up to
Conforming to EN 60947-5-1
Conforming to UL, CSA
For ambient temperature
U min.
I min.
Conforming to EN 60947-5-1 and VDE 0660. gG fuse A
Conforming to EN 60947-5-1, I rms
Permissible for:
Guaranteed between N/C and N/O contacts
Guaranteed between N/C and N/O on LAD-C22
Ambient air temperature for operation
Repeat accuracy
Drift up to 0.5 million operating cycles
Drift depending on ambient air temperature
In millions of operating cycles
TeSys contactors
Auxiliary contact blocks without
dust and damp protected contacts
for model d contactors
Schemes:
pages 2/48 and 2/49
1 s
500 ms
100 ms
60 °C
V
V
V
A
Hz
V
mA
A
A
A
A
M
ms
ms
°C
°C
°C
°C
m
mm
mm
2
2
1, 2 or 4
690
690
600
10
25…400
17
5
10
": 140; $: 250
100
120
140
> 10
1.5 (on energisation and on de-energisation)
1.5
30
See page 2/40
LAD-N or C LAD-T & S
IEC 947-5-1, NF C 63-140, VDE 0660, EN 60947-5-1
UL, CSA
“TH”
Protection against direct finger contact IP 2X
- 60…+ 80
- 5…+ 60
- 40…+ 70
3000
Min.: 1 x 1; max.: 2 x 2.5
Max.: 2 x 2.5
0.25 % per °C 0.25 % per °C –
2
- 40…+ 70
± 2 %
+ 15 %
5
LAD-R
2
- 40…+ 70
± 2 %
+ 15 %
5
Schneider Electric
LAD-8
2
30

Related parts for LC1D18BL