XTCE050D00A EATON CUTLER HAMMER, XTCE050D00A Datasheet - Page 109

Non-Reversing Contactor

XTCE050D00A

Manufacturer Part Number
XTCE050D00A
Description
Non-Reversing Contactor
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTCE050D00A

No. Of Poles
3
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
120V
Relay Terminals
Screw Clamp
Nom Operating Power
30kW
Contact Voltage Ac Nom
690V
Contact Current Max
50A
Mounting Type
Panel Or DIN Rail
Operating Voltage
690VAC
Switching Power Ac1
10hp
Switching Power Ac3
50hp
Switching Current Ac1
80A
Switching Current Ac3
50A
Load Current Inductive
50A
Load Current Resistive
80A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Table 34-135. XTOB Overload Relay — Technical Data and Specifications (Continued)
Auxiliary and Control Circuit Connections (Continued)
Tripping Characteristics
These tripping characteristics are the mean values of the spread at 20°C ambient temperature in a cold state.
Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay
reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found in
MN03402001E.
Figure 34-82. Tripping Characteristics
Instructional Leaflets
Table 34-136. Instructional Leaflets
CA08102001E
Description
Rated Operational Current —
Rated Operational Current —
Short Circuit Rating without Welding
Maximum Fuse, A gG/gl
Publication
Number
Pub51221
Pub51222
AC-15
DC-13 L/R ≤ 15 mS
Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.
Make Contact
Break Contact
110V
220V
120V
240V
415V
500V
120V
240V
415V
500V
24V
60V
100
0.6
2h
60
40
20
10
40
20
10
6
4
2
1
6
4
2
1
1
1.5 2
x Setting Current
Description
XTOB, D Frame Overload Relays (Inside of Packaging)
XTOB, B – C Frame Overload Relays (Inside of Packaging)
2-Phase
3 4
XTOB...BC1,
XTOB...CC1,
XTOB...DC1
6 8 10 15 20
3-Phase
XTOB…BC1, XTOB…CC1 XTOB…DC1
1.5
1.5
0.5
0.5
1.5
1.5
0.9
0.8
0.9
0.75
0.4
0.2
6
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Overload Relays — XTOB, XTOT
100
0.6
2h
60
40
20
10
40
20
10
6
4
2
1
6
4
2
1
1
1.5 2
x Setting Current
2-Phase
3 4
1.5
1.5
0.5
0.5
1.5
1.5
0.9
0.8
0.9
0.75
0.4
0.2
6
XTOB...GC1
6 8 10 15 20
3-Phase
XTOB…GC1, XTOB…GC1S XTOB...LC1
1.5
1.5
0.5
0.5
1.5
1.5
0.9
0.8
0.9
0.75
0.4
0.2
6
100
0.6
2h
60
40
20
10
40
20
10
6
4
2
1
6
4
2
1
1
1.5 2
x Setting Current
2-Phase
3 4
1.5
1.5
0.5
0.5
1.5
1.5
0.9
0.8
0.9
0.75
0.4
0.2
6
XTOB...LC1
6 8 10 15 20
3-Phase
34-109
34