XTCE050D00A EATON CUTLER HAMMER, XTCE050D00A Datasheet - Page 79

Non-Reversing Contactor

XTCE050D00A

Manufacturer Part Number
XTCE050D00A
Description
Non-Reversing Contactor
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTCE050D00A

No. Of Poles
3
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
120V
Relay Terminals
Screw Clamp
Nom Operating Power
30kW
Contact Voltage Ac Nom
690V
Contact Current Max
50A
Mounting Type
Panel Or DIN Rail
Operating Voltage
690VAC
Switching Power Ac1
10hp
Switching Power Ac3
50hp
Switching Current Ac1
80A
Switching Current Ac3
50A
Load Current Inductive
50A
Load Current Resistive
80A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Auxiliary Contacts
Table 34-117. Auxiliary Contacts Technical Data and Specifications
Table 34-118. Parallel Link Technical Data and Specifications
Table 34-119. Cable Terminal Block, Flat Cable Terminal Technical Data and Specifications
CA08102001E
Description
Interlocked opposing contacts with an auxiliary
contact module (to IEC 60947-5 -1 Annex L)
Break contact (not late-break contact)
suitable as a mirror contact
(to IEC/EN 60947-4 -1 Annex F)
Rated impulse withstand voltage, (U imp ) V AC
Overvoltage category / pollution degree
Rated insulation voltage, (U i ) V AC
Rated operational voltage, (U e ) V AC
Safe isolation to VDE 0106 Part 101 and
Part 101(A) in V AC
Rated Operational Current, l e
Conventional thermal current, I th
Control circuit reliability
(at U e = 24 V DC, U min = 17 V, I min = 5.4 mA)
Component Lifespan, Operations x 10
at U e = 230V, AC-15, 3A
Short-circuit rating without welding
Description
Terminal Capacity
Tightening Torque (Nm)
Tools
Conventional Thermal Current
Description
Terminal Capacity
Between coil and auxiliary contacts
Between the auxiliary contacts
AC-15
DC-3 L/R ≤5 mS
Maximum fuse, gG/gL
Solid (mm
Flexible with ferrule (mm
Stranded (mm
Flat conductor —
number of segments x width x thickness (mm)
Pozidriv screwdriver
Hexagon socket head spanner — SW (mm)
3-Pole (I th ) A
4-Pole (I th ) A
Stranded (mm
Stranded (AWG)
Flat conductor —
number of segments x width x thickness (mm)
Making and breaking conditions to DC-13, time L/R contact as stated.
See fuses overlay for time/current characteristic (on request).
Conventional thermal current (I th ) of XTCEXSCC_ is 10A.
230V
380/415V
500V
110V
220V
24V
60V
2
)
2
2
)
)
2
)
6
XTCE007B…–
XTCE032C
XTCE007B… –
XTCE032C
6000
III/3
690
500
400
400
6A
4A
1.5A
10A
6A
3A
1A
16A
1.3
10A
XTCEXPLKB
1 – 16
1 x (0.5 – 25)
2 x (0.5 – 16)
1 x (0.5 – 25)
2 x (0.5 – 16)
6 x 9 x 0.8
4
Size 2
50
60
XTCEXTLA400
1 x (120 – 300)
2 x (70 – 240)
1 x (1/0 – 600 MCM)
2 x (1/0 – 500 MCM)
1 x (10 x 16 x 0.8)
2 x (20 x 24 x 0.5)
2 x (11 x 21 x 1)
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters
XTCEXFAC…
XTCEXFATC...
Yes
XTCE007B… –
XTCE032C
6000
III/3
690
500
400
400
6A
3A
10A
6A
3A
1A
16A
1.3
10A
XTECXPLKC
16
1 x (16 – 35)
1 x (16 – 50)
4
Size 2
100
XTCEXPLK185
1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
<10
-8
, < one failure at 100 million operations
XTCEXFCC…
XTCEXSCC...
Yes
XTCE007B… –
XTCE032C
6000
III/3
690
500
400
400
6A
4A
1.5A
10A
6A
3A
1A
16A
1.3
10A
XTCEXPLKD
16
1 x (16 – 120)
1 x (16 – 120)
14
5
180
XTCEXTFB650
1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
XTCEXFAG…
Yes
XTCE040D… –
XTCE065D…
6000
III/3
690
500
440
440
6A
4A
1.5A
10A
6A
3A
1A
10A
1.3
16A
XTCEXPLKG
1 x (35 – 300)
2 x (35 – 120)
2 x (11 x 21 x 1)
6
400
XTCEXTFB820
1 x (6 x 16 x 0.8)
2 x (10 x 40 x 1)
2 x (20 x 40 x 0.5)
XTCEXSBLN…
XTCEXSBN…
XTCEXSBNC...
XTCEXSCN…
XTCEXSCNC…
Yes
XTCE040D… –
XTCE065D…
XTCE185L… –
XTCEC10N…
6000
500
440
440
6A
4A
1.5A
10A
6A
3A
1A
10A
1.3
XTCEXPLK185
1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
III/3
690
16A
34-79
34

Related parts for XTCE050D00A