G2PM400VSY20 TELE, G2PM400VSY20 Datasheet

RELAY, VOLTAGE MONITORING, 3-PHASE

G2PM400VSY20

Manufacturer Part Number
G2PM400VSY20
Description
RELAY, VOLTAGE MONITORING, 3-PHASE
Manufacturer
TELE
Series
GAMMAr
Datasheet

Specifications of G2PM400VSY20

Contact Configuration
DPCO
Power Consumption
1W
Supply Voltage Max
240V
Relay Mounting
DIN Rail
Svhc
No SVHC (18-Jun-2010)
Contact Current Ac Max
5A
Contact Voltage Ac Max
250V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Monitoring relays - GAMMA series
Multifunction
Monitoring of phase sequence and phase failure
Monitoring of asymmetry selectable
Connection of neutral wire optional
Detection of loss of neutral wire
Zoom voltage 24 to 240V AC/DC
2 change-over contacts
Width 22.5mm
Industrial design
Technical data
1. Functions
Voltage monitoring in 3-phase mains with adjustable thresholds,
adjustable tripping delay, monitoring of phase sequence and phase
failure, monitoring of asymmetry with adjustable threshold and the
following functions which are selectable by means of rotary switch:
2. Time ranges
Start-up suppression time:
Tripping delay:
3. Indicators
Red LED ON/OFF:
Red LED flashes:
Yellow LED ON/OFF:
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP40
Mounted on DIN-Rail TS 35 according to EN 60715
Mounting position: any
Shockproof terminal connection according to VBG 4 (PZ1 required),
IP rating IP20
Tightening torque: max. 1Nm
Terminal capacity:
5. Input circuit
Supply voltage:
Tolerance:
Rated frequency:
Rated consumption:
Duration of operation:
Reset time:
Wave form for AC:
Residual ripple for DC:
Drop-out voltage:
Overvoltage category:
surge voltage:
6. Output circuit
2 potential free change-over contacts
UNDER
UNDER+SEQ
WIN
WIN+SEQ
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
24 to 240V AC/DC
24 to 240V DC
24 to 240V AC
24 to 240V AC
48 to 240V AC
Voltage monitoring in 3-phase mains
Undervoltage monitoring
Undervoltage monitoring and monitoring of
phase sequence
Monitoring of window between Min and Max
Monitoring the window between Min and Max
and monitoring of phase sequence
Adjustment range
-
0.1s
indication of failure of the corresponding
threshold
indication of tripping delay of the
corresponding threshold
indication of relay output
terminals A1-A2 (galvanically separated)
-20% to +25%
-15% to +10%
48 to 400Hz
16 to 48Hz
4.5VA (1W)
100%
500ms
Sinus
10%
>15% of the supply voltage
III (in accordance with IEC 60661-1)Rated
4kV
10s
www.tele-online.com
Rated voltage:
Switching capacity:
If the distance between the devices is less than 5mm!
Switching capacity:
If the distance between the devices is greater than 5mm!
Fusing:
Mechanical life:
Electrical life:
Switching frequency:
Overvoltage category:
Rated surge voltage:
7. Measuring circuit
Fusing:
Measured variable:
Input:
Overload capacity:
Input resistance:
Switching threshold
Asymmetry:
Overvoltage category:
Rated surge voltage:
8. Accuracy
Base accuracy:
Frequency response:
Adjustment accuracy:
Repetition accuracy:
Voltage influence:
Temperature influence: ≤0.05% / °C
9. Ambient conditions
Ambient temperature:
Storage temperature:
Transport temperature: -25 to +70°C
Relative humidity:
Pollution degree:
Vibration resistance:
Shock resistance:
3(N)~ 115/66V
3(N)~ 230/132V
3(N)~ 400/230V
3(N)~ 115/66V
3(N)~ 230/132V
3(N)~ 400/230V
3(N)~ 115/66V
3(N)~ 230/132V
3(N)~ 400/230V
Max:
Min:
15g 11ms (in accordance with IEC 60068-2-27)
250V AC
750VA (3A / 250V AC)
1250VA (5A / 250V AC)
5A fast acting
20 x 10
2 x 10
at 1000VA resistive load
max. 60/min at 100VA resistive load
max. 6/min at 1000VA resistive load
(in accordance with IEC 60947-5-1)
III (in accordance with IEC 60664-1)
4kV
max. 20A (in accordance with UL 508)
AC Sinus (48 to 63Hz)
terminals (N)-L1-L2-L3 (G2PM115VSY20)
terminals (N)-L1-L2-L3 (G2PM230VSY20)
terminals (N)-L1-L2-L3 (G2PM400VSY20)
3(N)~173/100V (G2PM115VSY20)
3(N)~345/199V (G2PM230VSY20)
3(N)~600/346V (G2PM400VSY20)
220kΩ (G2PM115VSY20)
470kΩ (G2PM230VSY20)
1MΩ (G2PM400VSY20)
-20% to +30% of UN
-30% to +20% of UN
5% to 25%
III (in accordance with IEC 60664-1)
4kV
≤3% (of maximum scale value)
-
≤5% (of maximum scale value)
≤2%
-
-25 to +55°C (in accordance with IEC 60068-1)
-25 to +40°C (in accordance with UL 508)
-25 to +70°C
15% to 85%
(in accordance with IEC 60721-3-3 class 3K3)
3 (in accordance with IEC 60664-1)
10 to 55Hz 0.35mm
(in accordance with IEC 60068-2-6)
G2PMSY...20 24-240V
5
6
operations
operations

Related parts for G2PM400VSY20

G2PM400VSY20 Summary of contents

Page 1

... IEC 60947-5-1) III (in accordance with IEC 60664-1) 4kV max. 20A (in accordance with UL 508) AC Sinus (48 to 63Hz) terminals (N)-L1-L2-L3 (G2PM115VSY20) terminals (N)-L1-L2-L3 (G2PM230VSY20) terminals (N)-L1-L2-L3 (G2PM400VSY20) 3(N)~173/100V (G2PM115VSY20) 3(N)~345/199V (G2PM230VSY20) 3(N)~600/346V (G2PM400VSY20) 220kΩ (G2PM115VSY20) 470kΩ (G2PM230VSY20) 1MΩ (G2PM400VSY20) ...

Page 2

... LED ASYM flashes). After the interval has expired (red LED ASYM illuminated), the output relays switch into off-position (yellow LED not illuminated). A break of the neutral wire between our device and the machinery can not be detected. www.tele-online.com G2PM...SY20 24-240V L3 Delay ...

Page 3

... Connections G2PM400VSY20 24-240V, supply voltage 24V AC/DC 24VAC/ G2PM400VSY20 24-240V, supply voltage 230V AC F1-3 max. 20A RELEASE 2009/07 Subject to alterations and errors Dimensions F1-3 max. 20A www.tele-online.com G2PM...SY20 24-240V ...

Related keywords