D2-2012-23-5024-WTL DURAKOOL, D2-2012-23-5024-WTL Datasheet

POWER RELAY DPDT-2CO 24VAC, 12A, PLUG IN

D2-2012-23-5024-WTL

Manufacturer Part Number
D2-2012-23-5024-WTL
Description
POWER RELAY DPDT-2CO 24VAC, 12A, PLUG IN
Manufacturer
DURAKOOL
Datasheet

Specifications of D2-2012-23-5024-WTL

Relay Type
General Purpose
Coil Voltage Vac Nom
24V
Contact Current Max
12A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Coil Resistance
158ohm
Contact Configuration
DPCO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Page 1 of 5
D2
industrial relays
Standard contact materials are marked with bold type.
❶ For plug-in sockets version: standard (WT) ❷ For PCB version ❸ For version with threaded bolt
Contacts
Contact number & arrangement
Contact material
Max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Resistance
Max. operating frequency
• at rated load
• no load
Coil
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
Insulation
Insulation category
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• coil - contact
• contact - contact
• pole - pole
Contact - coil distance
• clearance
• creepage
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cosφ
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storage
• operating
Cover protection category
Environmental protection
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
www.aecsensors.com
12 A / 250 V AC
50/60 Hz AC
(NO/NC)
AC/DC
AC1
DC1
AC1
AC1
Sales Department Tel: (888) 847-6552
DC
AC
DC
• Miniature dimensions • Cadmium - free contacts • AC and DC coils
• For plug-in sockets, 35 mm DIN rail mount, EN 50022 or on panel
mounting • For PCB and soldering connections - option • General
purpose relays • WT (mechanical indicator + lockable front test button)
- standard features of relays for plug-in sockets. Relays may be provi-
ded with the test buttons type P (no latching) and plugs.
• Recognitions, certificates, directives: RoHS,
2C/O
AgNi, AgNi/Au 0.2 um, AgNi/Au 5 um
250 V / 250 V
5 V
12 A / 250 V AC ❶
12 A / 24 V DC ❶10 A / 24 V DC ❷
5 mA AgNi, 5 mA AgNi/Au 0.2 um, 2 mA AgNi/Au 5 um
24 A
12 A ❶
3 000 VA ❶
0.3 W AgNi, 0.3 W AgNi/Au 0.2 um, 0.1 W AgNi/Au 5 um
≤ 100 mΩ
1 200 cycles/hour
18 000 cycles/hour
6...240 V
5...220 V
AC: ≥ 0.2 U n
see Tables 1, 2
1,6 VA
0,9 W
C250
250 V AC
4 000 V AC
III
3
2 500 V AC
1 500 V AC
2 500 V AC
≥ 2.5 mm
≥ 4 mm
AC: 10 ms
AC: 8 ms
≥ 10 5
see Fig. 2
≥ 2 x 10 7
27.5 x 21.2 x 35.6 mm ❶ 27.5 x 21.1 x 33.5 mm ❷
27.5 x 21.2 x 33 mm ❸
35 g
-40...+85 o C
AC: -40...+55 o C DC: -40...+70 o C
IP 40
RTI
10 g / 5 g
5 g
max. 270 o C
max. 5 s
IEC 61810-5 (PN-IEC 664-1)
IEC 61810-7
10...150 Hz
12 A, 250 V AC
DC: ≥ 0.1 U n
DC: 13 ms
DC: 3 ms
10 A / 250 V AC ❷
10 A ❷
2 500 VA ❷
R
VDE

Related parts for D2-2012-23-5024-WTL

D2-2012-23-5024-WTL Summary of contents

Page 1

... D2 industrial relays 250 V AC Contacts Contact number & arrangement Contact material Max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance Max. operating frequency • at rated load • no load ...

Page 2

... D2 industrial relays Coil data - DC voltage version Coil code 1005 1006 1012 1024 1048 1060 1080 1110 1125 1220 Standard coil rated voltages marked with bold type. Coil data - AC 50/60 Hz voltage Coil code 5006 5012 5024 5042 5048 5060 5080 5110 5120 ...

Page 3

... D2 industrial relays Dimensions - plug-in version (WT), with lockable front test button type T 6.6 6.6 21.2 2.2x0.5 Dimensions - PCB version (without WT) 1 13.2 21.1 Dimensions - version with mounting flange in the upper wall of the cover (without WT 28.4 Page www.aecsensors.com Dimensions - plug-in version (WT), with test button type P (no latching) or with plug (no manual operation) Test buttons type P and plugs need to ordered separately ...

Page 4

... Mounting Relays D2 are offered in versions: sockets. In standard version of relays (WT) is possibility self-exchange of button type T for: button type P (no latching) or plug (no manual operation). Buttons type P and plugs need to ordered saparately for PCB (without WT) with threaded bolt • ...

Page 5

... D2, contact material AgNi, with two changeover contacts, in cover IP 40, for plug-in sockets, voltage version 24 V DC, with mechanical indicator and lockable front test button D2-2012-25-1024 relay D2, contact material AgNi, with two changeover contacts, in cover IP 40, for PCB, voltage version American Electronic Components, Inc. 1101 Lafayette Street, Elkhart, IN 46516 Page www ...