HE1AN-P-DC9V-Y5 PANASONIC EW, HE1AN-P-DC9V-Y5 Datasheet - Page 12

no-image

HE1AN-P-DC9V-Y5

Manufacturer Part Number
HE1AN-P-DC9V-Y5
Description
RELAY, POWER, SPST, 9VDC, 30A
Manufacturer
PANASONIC EW
Datasheet

Specifications of HE1AN-P-DC9V-Y5

Relay Type
Power
Coil Voltage Vdc Nom
9V
Contact Current Max
48A
Coil Resistance
42.2ohm
Coil Type
DC
Coil Current
213mA
Nom Operating Power
1920mW
Relay Mounting
Terminal Blade
External
RoHS Compliant
Contact Configuration
SPST
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HE1AN-P-DC9V-Y5
Manufacturer:
Panasonic Electric Works
Quantity:
135
HE
NOTES
conditions
1) Temperature:
–50 to +55C
–50 to +85C
applied coil hold voltage is 50% to 60% of
nominal coil voltage)
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
4) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
12
Usage, transport and storage
 –50 to +85C
coil hold voltage is 50% to 60% of nominal
coil voltage)
-50
-58
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
-50
-58
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
Tolerance range
Tolerance range
–58 to +131F
–58 to +185F
85
–58 to +185F
85
5
+32
5
+32
0
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
0
Humidity, %RH
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
Humidity, %RH
Temperature, °C
Temperature, °C
(When applied
+131
(When
55
°F
°F
+185
85
5) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0C 32F.
This causes problems such as sticking of
movable parts or operational time lags.
6) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
 Certification
This relay is C-UL certified.
This relay is certified by VDE as an
electromagnetic relay that complies with
VDE0435.
 Others
1) For precautions regarding use and
explanations of technical terminology,
please refer to our web site.
(panasonic-electric-works.net/ac)
2) To ensure good operation, please keep
the voltage on the coil ends to 5% (at
20C 68F) of the rated coil operation
voltage. Also, please be aware that the
pick-up voltage and drop-out voltage may
change depending on the temperature
and conditions of use.
3) Keep the ripple rate of the nominal coil
voltage below 5%.
4) The cycle lifetime is defined under the
standard test condition specified in the
JIS C 5442 standard (temperature 15 to
35C
Check this with the real device as it is
affected by coil driving circuit, load type,
activation frequency, activation phase,
ambient conditions and other factors.
Also, be especially careful of loads such
as those listed below.
(1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
48 A 277 V AC
48 A 250 V AC cos = 0.8
59 to
95F, humidity 25 to 85%).
(2) Highly frequent load-operating
When highly frequent opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO
can corrode metal materials.
Three countermeasures for these are
listed here.
• Incorporate an arc-extinguishing circuit.
• Lower the operating frequency
• Lower the ambient humidity
5) This value can change due to the
switching frequency, environmental
conditions, and desired reliability level,
therefore it is recommended to check this
with the actual load.
6) Heat, smoke, and even a fire may
occur if the relay is used in conditions
outside of the allowable ranges for the
coil ratings, contact ratings, operating
cycle lifetime, and other specifications.
Therefore, do not use the relay if these
ratings are exceeded.
7) If the relay has been dropped, the
appearance and characteristics should
always be checked before use.
8) Incorrect wiring may cause
unexpected events or the generation of
heat or flames.
ds_61C06_en_he: 150509D
3
is formed. This

Related parts for HE1AN-P-DC9V-Y5