W6440ASX-1 Magnecraft / Schneider Electric, W6440ASX-1 Datasheet

SSR, PANEL MOUNT, 480VAC, 280VAC, 40A

W6440ASX-1

Manufacturer Part Number
W6440ASX-1
Description
SSR, PANEL MOUNT, 480VAC, 280VAC, 40A
Manufacturer
Magnecraft / Schneider Electric
Datasheet

Specifications of W6440ASX-1

Control Voltage Range
90VAC To 280VAC
Operating Voltage Range
48VAC To 480VAC
Load Current
40A
Isolation Voltage
4000VAC
Control Voltage Type
AC
Relay Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Your Contact for Relays
2
SECTION
SOLID STATE RELAYS (SSR)
2.5 TO 125 AMPERES

Related parts for W6440ASX-1

W6440ASX-1 Summary of contents

Page 1

... Your Contact for Relays SECTION SOLID STATE RELAYS (SSR) 2.5 TO 125 AMPERES 2 ...

Page 2

... SCREW Recognized UL Recognized File No. E52197 File No. E52197 PAGE 8 CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 6 (ASX) L.E.D. STATUS LAMP 2.25 x 1.75 x 0.78 2.25 x 1.75 x 0.78 DC INPUT AC OUTPUT UP TO 125 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING 4000V rms ISOLATION INPUT ...

Page 3

... TO +100˚ Ω SCREW Recognized File No. E52197 PAGE 12 CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 6 (DTX) L.E.D. STATUS LAMP 2.25 x 1.75 x 0.78 DC INPUT AC TRIAC OUTPUT 10 AMP LOADS PHOTO ISOLATED ZERO VOLTAGE SWITCHING 4000V rms ISOLATION INPUT TO OUTPUT INTERNAL RC (SNUBBER) NETWORK ...

Page 4

... QUICK CONNECTS OR SCREW C UL Recognized TUV on 168986 Selected models File No. E52197 PAGE 16 PAGE CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 70S2 “ F ” & “ M ” STYLES 2.20 x 1.00 x 0.85 DC INPUT OUTPUT AMP LOADS OPTICALLY ISOLATED PRINTED CIRCUIT TERM OR PANEL ...

Page 5

... TO +125˚C 8.3 mS 8.3 mS Ω PRINTED CIRCUIT Recognized 168986 File No. E52197 PAGE CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 226 1.50 X 0.670 X 0.600 DC INPUT AC OUTPUT AMP LOADS PHOTO ISOLATED RANDOM TURN-ON COMPATABLE WITH TTL GATES MOUNTS TRANSISTOR HEAT SINKS ...

Page 6

... PRINCIPLE OF OPERATION: Solid State Relays are similar to electromechanical relays, in that both use a control circuit and a separate circuit for switching the load. When voltage is applied to the input of the SSR, the relay is energized by a light emitting diode. The light ...

Page 7

... SOLID STATE RELAYS CAPACITIVE LOADS: Caution must be used with low impedance capacitive loads to verify that the di/dt capabilities are not exceeded. The di/ discharged capacitive load without external limiting impedance can approach infinity. Zero voltage turn- particularly valuable means of limiting di/dt with capacitive loads ...

Page 8

... Line Frequency L = Inductance in Henrys C = Capacitance in Microfarads R & Resistance in Ohms 1 2 LOAD CURRENT AMPS PACK L PACK F PACK V PACK K PACK M PACK N PACK S PACK W6 series (DDX W6 series (DSX) W6 series (DTX) SSR-DIN-DC SSR-DIN-AC W6 series (ASX) W226 SOLID STATE RELAYS T rating which is a measure of the 125 PAGE ...

Page 9

SSRDIN CLASS AC & DC CONTROLLED INPUT INTEGRAL HEATSINK ONLY 30 MILLIMETERS WIDE PANEL/DIN MOUNTABLE (35 mm RAIL) FINGER SAFE COVER STATUS LAMP. 10 Amp Styles ...

Page 10

CLASS OUTLINE DIMENSIONS . DIMENSIONS SHOWN IN INCHES & (MILLIMETERS) 2.250 (57.2) 1.750 (44.5) RED L.E.D. INPUT OUTPUT 2.665 (67.691) 0.475 (12.065) 0.185 MAX. (4.699) 0.996 Max. (25.3) for 40 Amp DDX Models & for 75 to 125 Amps ...

Page 11

... PART RATED LOAD NUMBERS W6210ASX-1 *W6225ASX-1 W6240ASX-1 W6250ASX-1 W6275ASX-1 W6410ASX-1 W6425ASX-1 W6440ASX-1 W6450ASX-1 W6475ASX-1 W6690ASX-1 W66125ASX-1 * Approved On selected models W66 125 Amp 1000 uS 500 mA 1800 1.8 VAC 5800 0.14 +fan +fan ...

Page 12

CLASS DC CONTROLLED INPUT AC SCR OUTPUT STATUS LAMP. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated ...

Page 13

CLASS DC CONTROLLED INPUT DC MOSFET OUTPUT STATUS LAMP. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated Load Current: Minimum ...

Page 14

CLASS DC CONTROLLED INPUT AC TRIAC OUTPUT STATUS LAMP. NORMALLY OPEN OR NORMALLY CLOSED CONTACTS. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT ...

Page 15

CLASS DC CONTROLLED INPUT AC DOUBLE-POLE OUTPUT STATUS LAMP. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load ...

Page 16

... ORDERING CODE FOR RELA ORDERING CODE FOR RELA 70S2- 04- CLASS: CONTROLVOLTAGE VDC, DC/DC RELAYS VDC, DC/DC RELAYS VDC COMPACT RELAY VDC (OR 32 VDC), DC/AC RELAYS VDC (OR 32 VDC), DC/AC RELAYS CONTROLVOLTAGE 3-60 VDC B = 120 VAC C = 240 VAC VAC MAX CURRENT RATING 02 = 2.5 A ...

Page 17

CLASS DC CONTROLLED INPUT OUTPUT. Figure 1: Maximum Continuous Current vs. Ambient Temperature -40˚ -20˚ 0˚ 20˚ 40˚ 60˚ 80˚ 100˚ AMBIENT TEMPERATURE (C˚) GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Style: Control Voltage ...

Page 18

... Min. Insulation Resistance : 10 10 Operating Temperature Range: -40°C to +100°C Storage Temperature Range: -40°C to +125°C Weight: 47 grams approx. 2... 17 SOLID STATE “N” & “S” STYLE RELAYS DC CONTROLLED INPUT OUTPUT. STYLE N STYLE S TIONS TIONS 70S2-05-B 70S2-04-C 70S2-05 VDC ...

Page 19

... TERMINALS 2 TERMINALS 0.187 (4.75) 0.187 (4.75) STYLE N STYLE S FEATURES * OPTICALLY ISOLATED. * PANEL MOUNT. * SWITCHES AMP LOADS * MOUNTS ON CLASS 6 RELAY CENTERS, YET NEEDS 1/2 THE SPACE * SCREW TERMINALS OR PUSH - ON QC TERMINALS * LIFETIME WARRANTY SOLID STATE “N” & “S” STYLE RELAYS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & ...

Page 20

... Output Insulation): 3000 V rms Insulation Resistance: Operating Temperature Range: -40°C to +100°C Storage Temperature Range: -40°C to +125°C Weight: 35 grams approx. 2... 19 SOLID STATE “F” & “M” STYLE RELAYS DC CONTROLLED INPUT OUTPUT. STYLE F STYLE M TIONS TIONS 70S2-05-B 70S2-04 VDC VDC 6 ...

Page 21

CLASS 2.200 (55.88) 0.850 (21.59)MAX. 1.870 (47.50) 1.200 (30.48) 0.176 (4.47) 0.400 (10.16) 0.300 (7.62) 4 SQ. PINS 0.025 (0.64) FEATURES * OPTICALLY ISOLATED. * PANEL OR PRINTED CIRCUIT MOUNT. * SWITCHES ...

Page 22

... V rms. Min. Insulation Resistance: 10 Operating Temperature Range: -40°C to +100°C Storage Temperature Range: -40°C to +125°C Weight Style Style L approx. 2... 21 SOLID STATE “H” & “L” STYLE RELAYS DC CONTROLLED INPUT AC OUTPUT. 80˚ 100˚ STYLE H STYLE L TIONS TIONS 70S2-05-D ...

Page 23

... PRINTED CIRCUIT MOUNT * SWITCHES AMP LOADS * ONLY 0.5” ABOVE BOARD * MINIMAL BOARD SPACE REQUIRED * LIFETIME WARRANTY SOLID STATE “H” & “L” STYLE RELAYS OUTLINE DIMENSIONS . DIMENSIONS SHOWN IN INCHES & (MILLIMETERS) 1.200 (30.48) 0.516 (13.1) MAX. 0.600 (15.24) 1.000 (25 ...

Page 24

CLASS DC CONTROLLED INPUT OUTPUT SOCKET MOUNTABLE GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS 70S2-04-B 70S2-04-C 70S2-04-D Style: Control Voltage Range VDC VDC VDC Typical Input Current: 1 ...

Page 25

CLASS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS) 1.200 (30.48) TERMINAL BOTTOM VIEW SEE NOTE 2 0.232 (5.84) 0.285 (7.23) 0.280 (7.11) FEATURES * OPTICALLY ISOLATED * QUICK CONNECT/ SOLDER PLUG-IN MOUNT * MATES WITH 70-459-1 SOCKET * ...

Page 26

... OUTPUT 140 OR 280 VAC AMPS LOAD R1 MOLEX WINCHESTER 02-06-1103 156-10185 02-06-1132 156-10245 * OPTICALLY ISOLATED. * PANEL MOUNT. * SWITCHES AMP LOADS. * RANDOM VOLTAGE TURN ON. * PRINTED CIRCUIT OR PUSH - ON TERMINAL PIN VERSIONS. * LIFETIME WARRANTY. DC MAX. MIN. FIGURE CONTROLLED DROP-OUT PULL - IN INPUT 5 VDC 1 ...

Page 27

... SECTION MAGNECRAFT MAGNECRAFT CRYDOM CRYDOM & STRUTHERS-DUNN & STRUTHERS-DUNN W6210ASX-1 A2410 W6225ASX-1 A2425 W6240ASX-1 A2440 W6250ASX-1 A2450 W6275ASX-1 A2475 W6410ASX-1 - W6425ASX-1 HA4825 W6440ASX-1 - W6450ASX-1 HA4850 W6475ASX-1 HA4875 W6690ASX-1 A2490/HA4890 W66125ASX-1 A24125/HA48125 W6210DSX-1 D2410 W6225DSX-1 D2425 W6240DSX-1 - W6250DSX-1 D2450 W6275DSX-1 D2475 W6410DSX-1 ...

Page 28

... Your Contact for Relays SECTION SECTION MAGNECRAFT MAGNECRAFT & STRUTHERS-DUNN & STRUTHERS-DUNN 70S2-01-A-05-S 70S2-02-A-05-S 70S2-03-B-25-S 70S2-04-B-06-S 70S2-04-B-12-S 70S2-04-C-06-S 70S2-04-C-12-S 70S2-03-C-25-S THE CROSS REFERENCE IS INTENDED TO MATCH FOOT PRINT, INTERNAL WIRING, AND CONTACT LOAD RATINGS. CONSTRUCTION FEATURES AND GENERAL SPECIFICATIONS SHOULD BE COMPARED IF EXACT REPLACEMENT IS REQUIRED. ...

Related keywords