W6440ASX-1 Magnecraft / Schneider Electric, W6440ASX-1 Datasheet
W6440ASX-1
Specifications of W6440ASX-1
Related parts for W6440ASX-1
W6440ASX-1 Summary of contents
Page 1
... Your Contact for Relays SECTION SOLID STATE RELAYS (SSR) 2.5 TO 125 AMPERES 2 ...
Page 2
... SCREW Recognized UL Recognized File No. E52197 File No. E52197 PAGE 8 CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 6 (ASX) L.E.D. STATUS LAMP 2.25 x 1.75 x 0.78 2.25 x 1.75 x 0.78 DC INPUT AC OUTPUT UP TO 125 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING 4000V rms ISOLATION INPUT ...
Page 3
... TO +100˚ Ω SCREW Recognized File No. E52197 PAGE 12 CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 6 (DTX) L.E.D. STATUS LAMP 2.25 x 1.75 x 0.78 DC INPUT AC TRIAC OUTPUT 10 AMP LOADS PHOTO ISOLATED ZERO VOLTAGE SWITCHING 4000V rms ISOLATION INPUT TO OUTPUT INTERNAL RC (SNUBBER) NETWORK ...
Page 4
... QUICK CONNECTS OR SCREW C UL Recognized TUV on 168986 Selected models File No. E52197 PAGE 16 PAGE CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 70S2 “ F ” & “ M ” STYLES 2.20 x 1.00 x 0.85 DC INPUT OUTPUT AMP LOADS OPTICALLY ISOLATED PRINTED CIRCUIT TERM OR PANEL ...
Page 5
... TO +125˚C 8.3 mS 8.3 mS Ω PRINTED CIRCUIT Recognized 168986 File No. E52197 PAGE CONSULT FACTORY FOR OTHER CONFIGURATIONS SOLID STATE RELAYS 226 1.50 X 0.670 X 0.600 DC INPUT AC OUTPUT AMP LOADS PHOTO ISOLATED RANDOM TURN-ON COMPATABLE WITH TTL GATES MOUNTS TRANSISTOR HEAT SINKS ...
Page 6
... PRINCIPLE OF OPERATION: Solid State Relays are similar to electromechanical relays, in that both use a control circuit and a separate circuit for switching the load. When voltage is applied to the input of the SSR, the relay is energized by a light emitting diode. The light ...
Page 7
... SOLID STATE RELAYS CAPACITIVE LOADS: Caution must be used with low impedance capacitive loads to verify that the di/dt capabilities are not exceeded. The di/ discharged capacitive load without external limiting impedance can approach infinity. Zero voltage turn- particularly valuable means of limiting di/dt with capacitive loads ...
Page 8
... Line Frequency L = Inductance in Henrys C = Capacitance in Microfarads R & Resistance in Ohms 1 2 LOAD CURRENT AMPS PACK L PACK F PACK V PACK K PACK M PACK N PACK S PACK W6 series (DDX W6 series (DSX) W6 series (DTX) SSR-DIN-DC SSR-DIN-AC W6 series (ASX) W226 SOLID STATE RELAYS T rating which is a measure of the 125 PAGE ...
Page 9
SSRDIN CLASS AC & DC CONTROLLED INPUT INTEGRAL HEATSINK ONLY 30 MILLIMETERS WIDE PANEL/DIN MOUNTABLE (35 mm RAIL) FINGER SAFE COVER STATUS LAMP. 10 Amp Styles ...
Page 10
CLASS OUTLINE DIMENSIONS . DIMENSIONS SHOWN IN INCHES & (MILLIMETERS) 2.250 (57.2) 1.750 (44.5) RED L.E.D. INPUT OUTPUT 2.665 (67.691) 0.475 (12.065) 0.185 MAX. (4.699) 0.996 Max. (25.3) for 40 Amp DDX Models & for 75 to 125 Amps ...
Page 11
... PART RATED LOAD NUMBERS W6210ASX-1 *W6225ASX-1 W6240ASX-1 W6250ASX-1 W6275ASX-1 W6410ASX-1 W6425ASX-1 W6440ASX-1 W6450ASX-1 W6475ASX-1 W6690ASX-1 W66125ASX-1 * Approved On selected models W66 125 Amp 1000 uS 500 mA 1800 1.8 VAC 5800 0.14 +fan +fan ...
Page 12
CLASS DC CONTROLLED INPUT AC SCR OUTPUT STATUS LAMP. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated ...
Page 13
CLASS DC CONTROLLED INPUT DC MOSFET OUTPUT STATUS LAMP. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Power Indicator: OUTPUT CHARACTERISTICS Style: Load Voltage Range: Rated Load Current: Minimum ...
Page 14
CLASS DC CONTROLLED INPUT AC TRIAC OUTPUT STATUS LAMP. NORMALLY OPEN OR NORMALLY CLOSED CONTACTS. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input Current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT ...
Page 15
CLASS DC CONTROLLED INPUT AC DOUBLE-POLE OUTPUT STATUS LAMP. GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Control Voltage Range: Typical Input current: Must Release Voltage: Reverse Polarity Protection: Power Indicator: OUTPUT CHARACTERISTICS Load Voltage Range: Rated Load ...
Page 16
... ORDERING CODE FOR RELA ORDERING CODE FOR RELA 70S2- 04- CLASS: CONTROLVOLTAGE VDC, DC/DC RELAYS VDC, DC/DC RELAYS VDC COMPACT RELAY VDC (OR 32 VDC), DC/AC RELAYS VDC (OR 32 VDC), DC/AC RELAYS CONTROLVOLTAGE 3-60 VDC B = 120 VAC C = 240 VAC VAC MAX CURRENT RATING 02 = 2.5 A ...
Page 17
CLASS DC CONTROLLED INPUT OUTPUT. Figure 1: Maximum Continuous Current vs. Ambient Temperature -40˚ -20˚ 0˚ 20˚ 40˚ 60˚ 80˚ 100˚ AMBIENT TEMPERATURE (C˚) GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS Style: Control Voltage ...
Page 18
... Min. Insulation Resistance : 10 10 Operating Temperature Range: -40°C to +100°C Storage Temperature Range: -40°C to +125°C Weight: 47 grams approx. 2... 17 SOLID STATE “N” & “S” STYLE RELAYS DC CONTROLLED INPUT OUTPUT. STYLE N STYLE S TIONS TIONS 70S2-05-B 70S2-04-C 70S2-05 VDC ...
Page 19
... TERMINALS 2 TERMINALS 0.187 (4.75) 0.187 (4.75) STYLE N STYLE S FEATURES * OPTICALLY ISOLATED. * PANEL MOUNT. * SWITCHES AMP LOADS * MOUNTS ON CLASS 6 RELAY CENTERS, YET NEEDS 1/2 THE SPACE * SCREW TERMINALS OR PUSH - ON QC TERMINALS * LIFETIME WARRANTY SOLID STATE “N” & “S” STYLE RELAYS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & ...
Page 20
... Output Insulation): 3000 V rms Insulation Resistance: Operating Temperature Range: -40°C to +100°C Storage Temperature Range: -40°C to +125°C Weight: 35 grams approx. 2... 19 SOLID STATE “F” & “M” STYLE RELAYS DC CONTROLLED INPUT OUTPUT. STYLE F STYLE M TIONS TIONS 70S2-05-B 70S2-04 VDC VDC 6 ...
Page 21
CLASS 2.200 (55.88) 0.850 (21.59)MAX. 1.870 (47.50) 1.200 (30.48) 0.176 (4.47) 0.400 (10.16) 0.300 (7.62) 4 SQ. PINS 0.025 (0.64) FEATURES * OPTICALLY ISOLATED. * PANEL OR PRINTED CIRCUIT MOUNT. * SWITCHES ...
Page 22
... V rms. Min. Insulation Resistance: 10 Operating Temperature Range: -40°C to +100°C Storage Temperature Range: -40°C to +125°C Weight Style Style L approx. 2... 21 SOLID STATE “H” & “L” STYLE RELAYS DC CONTROLLED INPUT AC OUTPUT. 80˚ 100˚ STYLE H STYLE L TIONS TIONS 70S2-05-D ...
Page 23
... PRINTED CIRCUIT MOUNT * SWITCHES AMP LOADS * ONLY 0.5” ABOVE BOARD * MINIMAL BOARD SPACE REQUIRED * LIFETIME WARRANTY SOLID STATE “H” & “L” STYLE RELAYS OUTLINE DIMENSIONS . DIMENSIONS SHOWN IN INCHES & (MILLIMETERS) 1.200 (30.48) 0.516 (13.1) MAX. 0.600 (15.24) 1.000 (25 ...
Page 24
CLASS DC CONTROLLED INPUT OUTPUT SOCKET MOUNTABLE GENERAL SPECIFICA GENERAL SPECIFICA INPUT CHARACTERISTICS 70S2-04-B 70S2-04-C 70S2-04-D Style: Control Voltage Range VDC VDC VDC Typical Input Current: 1 ...
Page 25
CLASS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS) 1.200 (30.48) TERMINAL BOTTOM VIEW SEE NOTE 2 0.232 (5.84) 0.285 (7.23) 0.280 (7.11) FEATURES * OPTICALLY ISOLATED * QUICK CONNECT/ SOLDER PLUG-IN MOUNT * MATES WITH 70-459-1 SOCKET * ...
Page 26
... OUTPUT 140 OR 280 VAC AMPS LOAD R1 MOLEX WINCHESTER 02-06-1103 156-10185 02-06-1132 156-10245 * OPTICALLY ISOLATED. * PANEL MOUNT. * SWITCHES AMP LOADS. * RANDOM VOLTAGE TURN ON. * PRINTED CIRCUIT OR PUSH - ON TERMINAL PIN VERSIONS. * LIFETIME WARRANTY. DC MAX. MIN. FIGURE CONTROLLED DROP-OUT PULL - IN INPUT 5 VDC 1 ...
Page 27
... SECTION MAGNECRAFT MAGNECRAFT CRYDOM CRYDOM & STRUTHERS-DUNN & STRUTHERS-DUNN W6210ASX-1 A2410 W6225ASX-1 A2425 W6240ASX-1 A2440 W6250ASX-1 A2450 W6275ASX-1 A2475 W6410ASX-1 - W6425ASX-1 HA4825 W6440ASX-1 - W6450ASX-1 HA4850 W6475ASX-1 HA4875 W6690ASX-1 A2490/HA4890 W66125ASX-1 A24125/HA48125 W6210DSX-1 D2410 W6225DSX-1 D2425 W6240DSX-1 - W6250DSX-1 D2450 W6275DSX-1 D2475 W6410DSX-1 ...
Page 28
... Your Contact for Relays SECTION SECTION MAGNECRAFT MAGNECRAFT & STRUTHERS-DUNN & STRUTHERS-DUNN 70S2-01-A-05-S 70S2-02-A-05-S 70S2-03-B-25-S 70S2-04-B-06-S 70S2-04-B-12-S 70S2-04-C-06-S 70S2-04-C-12-S 70S2-03-C-25-S THE CROSS REFERENCE IS INTENDED TO MATCH FOOT PRINT, INTERNAL WIRING, AND CONTACT LOAD RATINGS. CONSTRUCTION FEATURES AND GENERAL SPECIFICATIONS SHOULD BE COMPARED IF EXACT REPLACEMENT IS REQUIRED. ...