A1201LLHLT-T Allegro Microsystems Inc, A1201LLHLT-T Datasheet - Page 11

IC SW CONTINUOUS TIME BIPO SOT23

A1201LLHLT-T

Manufacturer Part Number
A1201LLHLT-T
Description
IC SW CONTINUOUS TIME BIPO SOT23
Manufacturer
Allegro Microsystems Inc
Type
Bipolar Latchr
Datasheet

Specifications of A1201LLHLT-T

Sensing Range
50G Trip, -50G Release
Voltage - Supply
3.8 V ~ 24 V
Current - Supply
7.5mA
Current - Output (max)
25mA
Output Type
Digital, Open Drain
Features
Regulated Voltage
Operating Temperature
-40°C ~ 150°C
Package / Case
SOT-23W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
620-1007-2
A1201
Power Derating
The device must be operated below the maximum junction
temperature of the device, T
peak conditions, reliable operation may require derating sup-
plied power or improving the heat dissipation properties of the
application. This section presents a procedure for correlating
factors affecting operating T
the Allegro MicroSystems Web site.)
The Package Thermal Resistance, R
marizing the ability of the application and the device to dissipate
heat from the junction (die), through all paths to the ambient air.
Its primary component is the Effective Thermal Conductivity,
K, of the printed circuit board, including adjacent devices and
traces. Radiation from the die through the device case, R
relatively small component of R
T
overmolding.
The effect of varying power levels (Power Dissipation, P
be estimated. The following formulas represent the fundamental
relationships used to estimate T
V
A worst-case estimate, P
able power level (V
at a selected R
For example, given common conditions such as: T
A
CC
, and air motion are significant external factors, damped by
T = P
T = P
= 12 V, I
T
P
D
J
= T
= V
A
D
CC
+ T = 25°C + 7°C = 32°C
×
CC
JA
×
R
= 4 mA, and R
I
JA
and T
CC
P
T
CC(max)
D
J
= 12 V
= 48 mW
= T
= V
A
D(max)
.
A
D
IN
, I
+ ΔT
×
J(max)
J
CC(max)
×
×
. (Thermal data is also available on
, represents the maximum allow-
R
×
JA
4 mA = 48 mW
J
I
JA
JA
, at P
IN
. Under certain combinations of
140 °C/W = 7°C
. Ambient air temperature,
= 140 °C/W, then:
), without exceeding T
(2)
JA
D
.
, is a figure of merit sum-
(1)
(3)
A
= 25°C,
Power Derating
JC
D
), can
J(max)
, is
,
Continuous-Time Bipolar Switch
Example: Reliability for V
minimum-K PCB.
Observe the worst-case ratings for the device, specifically:
R
I
Calculate the maximum allowable power level, P
invert equation 3:
This provides the allowable increase to T
power dissipation. Then, invert equation 2:
P
Finally, invert equation 1 with respect to voltage:
The result indicates that, at T
dissipate adequate amounts of heat at voltages ≤V
Compare V
able operation between V
R
V
CC(max)
JA
JA
CC(max)
V
T
D(max)
CC(est)
. If V
= 165°C/W, T
max
= 7.5 mA.
is reliable under these conditions.
= T
= T
= P
CC(est)
CC(est)
J(max)
D(max)
max
≥ V
to V
J(max)
÷ R
– T
÷ I
CC(max)
JA
CC(max)
A
CC(max)
= 165°C, V
= 165 °C – 150 °C = 15 °C
= 15°C ÷ 165 °C/W = 91 mW
CC(est)
CC
115 Northeast Cutoff, Box 15036
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
, then operation between V
A
. If V
at T
= 91 mW ÷ 7.5 mA = 12.1 V
, the application and device can
and V
A
CC(est)
= 150°C, package UA, using
CC(max)
CC(max)
≤ V
J
= 24 V, and
resulting from internal
CC(max)
requires enhanced
D(max)
CC(est)
, then reli-
CC(est)
. First,
.
and
11

Related parts for A1201LLHLT-T