DS1822 Maxim Integrated Products, DS1822 Datasheet - Page 15

IC THERMOMETER ECONO DIG TO-92

DS1822

Manufacturer Part Number
DS1822
Description
IC THERMOMETER ECONO DIG TO-92
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1822

Sensing Temperature
-55°C ~ 125°C
Output Type
Digital
Voltage - Supply
3 V ~ 5 V
Accuracy
±2°C
Package / Case
TO-226-3, TO-92-3 (TO-226AA)
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1822
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1822+
Manufacturer:
MAXIM
Quantity:
3 400
Part Number:
DS1822Z
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1822Z+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1822Z+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1822Z+T&R
Manufacturer:
MAXIM
Quantity:
3
Part Number:
DS1822Z+T&R
0
Part Number:
DS1822Z+T/R
Manufacturer:
RENESAS
Quantity:
1 450
1-WIRE SIGNALING
The DS1822 uses a strict 1-Wire communication protocol to insure data integrity. Several signal types are
defined by this protocol: reset pulse, presence pulse, write 0, write 1, read 0, and read 1. All of these
signals, with the exception of the presence pulse, are initiated by the bus master.
INITIALIZATION PROCEDURE: RESET AND PRESENCE PULSES
All communication with the DS1822 begins with an initialization sequence that consists of a reset pulse
from the master followed by a presence pulse from the DS1822. This is illustrated in Figure 13. When the
DS1822 sends the presence pulse in response to the reset, it is indicating to the master that it is on the bus
and ready to operate.
During the initialization sequence the bus master transmits (T
low for a minimum of 480μs. The bus master then releases the bus and goes into receive mode (R
When the bus is released, the 5k pullup resistor pulls the 1-Wire bus high. When the DS1822 detects this
rising edge, it waits 15μs to 60μs and then transmits a presence pulse by pulling the 1-Wire bus low for
60μs to 240μs.
INITIALIZATION TIMING Figure 13
READ/WRITE TIME SLOTS
The bus master writes data to the DS1822 during write time slots and reads data from the DS1822 during
read time slots. One bit of data is transmitted over the 1-Wire bus per time slot.
WRITE TIME SLOTS
There are two types of write time slots: “Write 1” time slots and “Write 0” time slots. The bus master
uses a Write 1 time slot to write a logic 1 to the DS1822 and a Write 0 time slot to write a logic 0 to the
DS1822. All write time slots must be a minimum of 60μs in duration with a minimum of a 1μs recovery
time between individual write slots. Both types of write time slots are initiated by the master pulling the
1-Wire bus low (see Figure 14).
To generate a Write 1 time slot, after pulling the 1-Wire bus low, the bus master must release the 1-Wire
bus within 15μs. When the bus is released, the 5k pullup resistor will pull the bus high. To generate a
Write 0 time slot, after pulling the 1-Wire bus low, the bus master must continue to hold the bus low for
the duration of the time slot (at least 60μs).
1-WIRE BUS
GND
V
PU
MASTER T
480μs minimum
X
waits 15-60μs
RESET PULSE
DS1822
LINE TYPE LEGEND
Bus master pulling low
DS1822 pulling low
Resistor pullup
15 of 21
presence pulse
DS1822 T
X
60-240μs
) the reset pulse by pulling the 1-Wire bus
480μs minimum
MASTER R
X
X
DS1822
X
).

Related parts for DS1822