E3XCN22 Omron, E3XCN22 Datasheet - Page 15

Sensor Connector

E3XCN22

Manufacturer Part Number
E3XCN22
Description
Sensor Connector
Manufacturer
Omron
Datasheet

Specifications of E3XCN22

Accessory Type
Amplifier Cable
For Use With
Digital Fiber Amplifier
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
General
• The four types of teaching given below are available.
• Once setting is made, operation is performed in the preset status thereafter. When a teaching error occurs, the level indicators
Maximum Sensitivity Setting
One-point without-object teaching
Note: If one-point teaching is not available because the difference in level is too
Operation Mode Selector
There is no operation mode selector for twin-output models.
E3X-DA-N
Proce-
Proce-
dure
dure
Light ON
Dark ON
flash in red. Restart setting from the beginning.
1
2
3
4
1
2
3
4
5
Twin-output models only
Set the mode selector to
fine, try two-point teaching.
Press the SET button once
(about 1 s).
Set the mode selector to SET.
Press the TEACH button for 3
seconds min.
Setting is completed when the
red-lit level indicators turn to
green. Then they return to the
digital incident level display.
Set to RUN mode.
Set the mode selector to SET.
Setting is completed when the
red level indicators are turned
ON. They then return to the digi-
tal incident level display.
Set to RUN mode.
The threshold is automatically
set with the object.
Operating mode
D ON
L ON
SET
Select the channel to be adjusted using the channel selection switch.
Operation
Operation
.
SET
L
When teaching is performed (SET mode)
D
Output
(Factory-set)
Operation
TEACH
TEACH
Object
ON
SET
SET
RUN
RUN
3s
1s
(red)
(green)
(red)
Two-point With/Without-object Teaching
Note: With and without work may be in any order.
Pin-point teaching (for positioning)
Proce-
Proce-
dure
dure
1
2
3
4
5
6
1
2
3
4
5
6
Set the mode selector to SET.
With the work present, press the
SET button once (about 1 s).
The level indicators are lit red.
If no work is pending, press the
SET button once (about 1 s).
Setting is completed when the
green indicators are turned ON.
Then they return to the digital in-
cident level display.
Set to RUN mode.
Set the mode selector to SET.
If no work is pending, press the
SET button once (about 1 s).
The level indicators are lit red.
Place the object in the desired
position, and press the TEACH
button for 3 seconds min.
Setting is completed when the
green indicators are turned ON.
Then they return to the digital in-
cident level display. (Red indica-
tors start flashing if setting is not
OK.)
Set to RUN mode.
CH1
CH2
Operation
Operation
TEACH
TEACH
TEACH
TEACH
Object
SET
SET
Object
RUN
RUN
1s
3s
1s
1s
A-433
(green)
(red)
(green)
(red)

Related parts for E3XCN22